2012
DOI: 10.1016/j.drudis.2012.02.008
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis and small molecule drug discovery: a perfect match?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0
1

Year Published

2013
2013
2017
2017

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 31 publications
(25 citation statements)
references
References 60 publications
0
24
0
1
Order By: Relevance
“…To find the suitable conditions for the chiral separation of the model molecules, a series of preliminary experiments were conducted with different buffer compositions at different pH values, in order to characterize the electrophoretic behavior of the analytes in an achiral system over a wide adjustable pH range (2)(3)(4)(5)(6)(7)(8)(9)(10)(11). In the preliminary analysis we used: 25 mM phosphoric acid (pH -2.1), 25 mM sodium didydrogenophosphate (pH -5.0), 25 mM disodium hydrogenophosphate -sodium didydrogenophosphate (1:1) (pH -7.0) and 25 mM sodium tetraborate (pH -9.3) BGEs respectively and we modified the pH of the buffer by adding a 0.1M sodium hydroxide solution.…”
Section: Resultsmentioning
confidence: 99%
“…To find the suitable conditions for the chiral separation of the model molecules, a series of preliminary experiments were conducted with different buffer compositions at different pH values, in order to characterize the electrophoretic behavior of the analytes in an achiral system over a wide adjustable pH range (2)(3)(4)(5)(6)(7)(8)(9)(10)(11). In the preliminary analysis we used: 25 mM phosphoric acid (pH -2.1), 25 mM sodium didydrogenophosphate (pH -5.0), 25 mM disodium hydrogenophosphate -sodium didydrogenophosphate (1:1) (pH -7.0) and 25 mM sodium tetraborate (pH -9.3) BGEs respectively and we modified the pH of the buffer by adding a 0.1M sodium hydroxide solution.…”
Section: Resultsmentioning
confidence: 99%
“…To meet the increasing demand for HTS of kinase activity modulators, assay technologies have evolved rapidly in recent years. Efficient and comprehensive screening of enzyme activity with suitable sample throughput was accomplished by using capillary array electrophoresis as well as multichannel microfluidic electrophoresis coupled with multiplexed optical (UV, LIF), conductivity, and MS detectors . The goal is to decrease analysis time particularly by performing parallel assays.…”
Section: High‐throughput and Multiplex Approachesmentioning
confidence: 99%
“…. Other applications can be found in different remarkable reviews on CE enzyme assays in general and on EMMA or TDLFP specifically .…”
Section: Introductionmentioning
confidence: 99%
“…These analyses have been summarized elsewhere, for example, in [25][26][27][28] and are not included in the present review either. For earlier compilations of the use of capillary electromigration methods in drug analysis see, for example, [7,[10][11][12][29][30][31][32][33][34].…”
Section: Introductionmentioning
confidence: 99%