1999
DOI: 10.1177/000992289903800303
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Refill Time in the Hands and Feet of Normal Newborn Infants

Abstract: We measured capillary refill time (CRT) in a convenience sample of 137 healthy newborns between 1 and 120 hours of age and 36-42 weeks gestation in the well-baby nursery of a large community hospital. CRT was measured by applying moderate pressure to the dorsum of the right hand and right foot for 5 seconds. Pressure was released and the time for complete refilling of the blanched area noted. Each infant was studied only once. We also measured ambient temperature and the skin temperature of the dorsum of the h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
48
0

Year Published

2001
2001
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(49 citation statements)
references
References 10 publications
1
48
0
Order By: Relevance
“…Capillary refill time is influenced by ambient temperature, 25 site, and age and its interpretation can be influenced by lighting. 26 • Tachycardia is a common sign of shock, but it can also result from other causes, such as pain, anxiety, and fever.…”
Section: Shockmentioning
confidence: 99%
“…Capillary refill time is influenced by ambient temperature, 25 site, and age and its interpretation can be influenced by lighting. 26 • Tachycardia is a common sign of shock, but it can also result from other causes, such as pain, anxiety, and fever.…”
Section: Shockmentioning
confidence: 99%
“…Clinical evaluation includes assessment of capillary refill time, skin colour, temperature and urine output. Capillary refill time values exist for term newborns [32], but there are limited data available for preterm infants [33,34]. Although there is a significant relationship between cardiac index (cardiac output/body surface area) and capillary refill time in preterm babies, there appears to be only a weak association between capillary refill and systemic blood flow [33].…”
Section: Evaluating Systemic Perfusionmentioning
confidence: 99%
“…At present there is a poor consensus on the "state of the art" [7][8][9][10][11]. Contentious issues are lack of standardization of the actual blanching manoeuvre and the dependency on subjective ("naked eye") assessment of the refill endpoint [8,10,12].…”
Section: Introductionmentioning
confidence: 99%