1997
DOI: 10.1016/s0021-9673(97)00176-3
|View full text |Cite
|
Sign up to set email alerts
|

Capillary zone electrophoretic determination of ionic impurities in silicone products used for electronic applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…(2) Effect of Incubation Temperature and Time. The effect of temperature (45, 60, 70, and 90 °C) and heating time (5,10,15, and 20 min) on rMAb fragmentation in the absence or presence of the alkylating agent (40 mM IAM) before CE-SDS analysis of nonreduced samples was studied. The pH level of these sample solutions for SDS-rMAb complexation was pH 9.0.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…(2) Effect of Incubation Temperature and Time. The effect of temperature (45, 60, 70, and 90 °C) and heating time (5,10,15, and 20 min) on rMAb fragmentation in the absence or presence of the alkylating agent (40 mM IAM) before CE-SDS analysis of nonreduced samples was studied. The pH level of these sample solutions for SDS-rMAb complexation was pH 9.0.…”
Section: Resultsmentioning
confidence: 99%
“…The emerging technique of capillary electrophoresis (CE) shows many advantages over classical SDS-PAGE including oncolumn direct UV or fluorescence detection, automation, enhanced resolution and reproducibility, and accurate quantification of proteins and molecular weight determination. [7][8][9][10][11][12][13][14] ableand water-soluble linear or slightly branched polymers, such as linear polyacrylamide, poly(ethylene oxide), 15 poly(ethylene glycol), dextran, and pullulan are used as the sieving matrix for CE-SDS. 8,[16][17][18][19] The implementation of these polymer solutions has led to the enhancement of overall precision and robustness of this CE-based methodology.…”
mentioning
confidence: 99%
“…As can be seen from the table, the large majority of studies showed no comparison data. For the few that did, the comparison has been mainly between CZE and IC [3,23,25,41,43,45,63,65,67,70,72,74,76,77,84,86,96,97,104,106,110,111,113,119,124,126,127,131,134,135,140,141,146,148,149,152,158,174,190,194,195,219]. Typical examples include studies by Yang et al [126], who found that results obtained using a high-sensitivity method developed using sample stacking technique together with the use of an internal standard correlated well with a standard IC method, and work by Fung and Lau [149], who examined a CZE method for the analysis of inorganic anions in rainwater and used an IC technique in parallel, reporting that the results for the major anions were within statistical variation.…”
Section: Evaluating Accuracymentioning
confidence: 99%
“…Accuracy can be achieved in one of two ways, firstly, through direct reference to a known standard, such as a quality control standard or certified reference material, or secondly, through reference to a standard analyzed using an alternative technique that is known to be accurate [218]. 110,111,113,119,124,126,127,131,134,135,140,141,146,148,149,152,158,174,190,194,195,219]. Typical examples include studies by Yang et al [126], who found that results obtained using a high-sensitivity method developed using sample stacking technique together with the use of an internal standard correlated well with a standard IC method, and work by Fung and Lau [149],…”
Section: Evaluating Accuracymentioning
confidence: 99%
“…The lifetimes of these columns were limited (usually less than 10 runs) [12], and the run-to-run reproducibility was poor. Currently, replaceable and water-soluble linear or slightly branched polymers, such as linear polyacrylamide [1113], poly(ethylene glycol) [11], poly(ethylene oxide) [14], dextran [1517], pullulan [18, 19] and cross-linked polyacrylamide [2022] are used as sieving matrices for CGE [5, 11, 2325]. Availability of these polymer matrices has led to improved reproducibility and robustness of this methodology.…”
Section: Introductionmentioning
confidence: 99%