2018
DOI: 10.1016/j.talanta.2018.07.005
|View full text |Cite
|
Sign up to set email alerts
|

Carbon black-based disposable sensor for an on-site detection of free chlorine in swimming pool water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 37 publications
0
14
0
3
Order By: Relevance
“…In detail, we tested 0.1 ppm of chlorine dioxide with the addition of 7.3 ppm NO 3 − , 13 ppm SO 4 2− , 11.3 ppm CO 3 2− , 14.5 ppm HCO 3 − , 1.8 ppm Cl − and again 0.1 ppm of chlorine dioxide. The interfering compound concentration was chosen in agreement with literature and our previous work . Figure shows the absence of detectable response towards interfering compounds, while maintaining the same sensitivity for chlorine dioxide.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In detail, we tested 0.1 ppm of chlorine dioxide with the addition of 7.3 ppm NO 3 − , 13 ppm SO 4 2− , 11.3 ppm CO 3 2− , 14.5 ppm HCO 3 − , 1.8 ppm Cl − and again 0.1 ppm of chlorine dioxide. The interfering compound concentration was chosen in agreement with literature and our previous work . Figure shows the absence of detectable response towards interfering compounds, while maintaining the same sensitivity for chlorine dioxide.…”
Section: Resultsmentioning
confidence: 99%
“…In according to our previous work , the Britton‐Robinson buffer solution was prepared by mixing the same concentration of acetic acid, phosphoric acid, and boric acid solution. Potassium chloride salt was chosen as support electrolyte and different amounts of sodium hydroxide were used to adjust the pH.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…128 Apesar da simplicidade, esse método não pode ser aplicado em medidas contínuas, uma vez que exige pré-tratamento da amostra e a maior parte dessas análises não podem ser feitas em fluxo. Nesse cenário, sensores eletroquímicos em conjunto com sistemas de análise em fluxo ou batelada são alternativas para essa abordagem, [129][130][131][132][133] por causa de sua sensibilidade, seletividade e particularmente pela possibilidade de analises in situ com pré-tratamentos simples nas amostras. Quando o hipoclorito de sódio é adicionado na água, um equilíbrio entre o ácido hipocloroso (HClO) e o íon hipoclorito (ClO -) é atingido.…”
Section: Sensores Amperométricos De Clorounclassified
“…O eletrodo modificado foi testado em amostras de água de piscina com uma recuperação ao redor de 79%. 132 Kabir e colaboradores demonstraram recentemente a determinação de CL utilizando um eletrodo de pseudo-grafite, uma nova forma de carbono semelhante ao grafite cristalino. 134 Utilizando um potencial de -0,15 V em fosfato de sódio pH= 7, foram obtidos um LD de 0,5 μmol L -1 e uma faixa linear de 200 a 2200 μmol L -1 .…”
Section: Sensores Amperométricos De Clorounclassified