2022
DOI: 10.1016/j.carrev.2022.01.028
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac Computed Tomography Angiography for Device-Related Thrombus Assessment After WATCHMAN FLX™ Occluder Device Implantation: A Single-Center Retrospective Observational Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…However, the conclusion was different in another recent single-center retrospective study[ 17 ]. Miller et al [ 17 ] included 43 patients who underwent Watchman FLX implantation from July 2020 to September 2021, and the final results showed that more than 40% of patients (17/43) implanted with Watchman FLX had PDL. Only 53% of patients (23/43) had complete closure of the LAA.…”
Section: Incidence Of Pdlmentioning
confidence: 57%
“…However, the conclusion was different in another recent single-center retrospective study[ 17 ]. Miller et al [ 17 ] included 43 patients who underwent Watchman FLX implantation from July 2020 to September 2021, and the final results showed that more than 40% of patients (17/43) implanted with Watchman FLX had PDL. Only 53% of patients (23/43) had complete closure of the LAA.…”
Section: Incidence Of Pdlmentioning
confidence: 57%
“…Meanwhile, it allows for a thorough evaluation of the atrial device surface, including the evaluation of hypoattenuated thickening (HAT) as a marker of contrast sparring. Several studies have suggested low-grade HAT as a proxy for benign endothelialization, while high-grade HAT has been associated with a higher thromboembolic risk [26,41,[89][90][91]. In one study, simultaneous CT and histology were performed in five canines, showing low-grade HAT to be associated with both macroscopic and histological evidence of neo-endothelialization [26].…”
Section: Device Healing-imagingmentioning
confidence: 99%
“…In one study, simultaneous CT and histology were performed in five canines, showing low-grade HAT to be associated with both macroscopic and histological evidence of neo-endothelialization [26]. Throughout several studies, HAT across the device surface on early follow-up CT has been observed in up to 61% and 64% of patients specifically implanted with Watchman FLX, while another study specifically evaluating ACP-and Amulet-implanted patients found HAT only in 6% of patients [26,41,91]. While this variability might suggest large differences in early endothelialization, the coupling of HAT with endothelial coverage needs additional validation.…”
Section: Device Healing-imagingmentioning
confidence: 99%
“…However, due to a lack of standardized definition of DRT on computed tomography angiography for WATCHMAN, guidelines are still in development, and additional studies are needed to determine standardized parameters for DRT diagnosis. 61 Additional use of serum biomarkers, such as the level of prothrombin fragments 1 + 2 and D-dimer, could be viable options and may potentially help us better understand and manage the post-WATCHMAN device implantation healing process. However, the relationship between these parameters and imaging-confirmed DRT is yet to be validated.…”
Section: The Rationale For Antithrombotic Therapymentioning
confidence: 99%