2015
DOI: 10.1186/s13014-015-0511-8
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac dose reduction with deep inspiration breath hold for left-sided breast cancer radiotherapy patients with and without regional nodal irradiation

Abstract: BackgroundDeep inspiration breath hold (DIBH) reduces heart and left anterior descending artery (LAD) dose during left-sided breast radiation therapy (RT); however there is limited information about which patients derive the most benefit from DIBH. The primary objective of this study was to determine which patients benefit the most from DIBH by comparing percent reduction in mean cardiac dose conferred by DIBH for patients treated with whole breast RT ± boost (WBRT) versus those receiving breast/chest wall plu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
52
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 95 publications
(57 citation statements)
references
References 23 publications
3
52
0
2
Order By: Relevance
“…(7) Our technique is similar to the voluntary breath-hold (VBH) technique used in the UK HeartSpare study; (13) however, the two techniques were developed independently. Bartlett et al (13) characterized the VBH technique using electronic portal imaging (EPID) and cone-beam CT. For offline EPID measurements, random and systematic errors of σ = 2.1 mm and Σ = 1.8 mm, respectively, were reported in the μ direction of the medial tangent beam.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…(7) Our technique is similar to the voluntary breath-hold (VBH) technique used in the UK HeartSpare study; (13) however, the two techniques were developed independently. Bartlett et al (13) characterized the VBH technique using electronic portal imaging (EPID) and cone-beam CT. For offline EPID measurements, random and systematic errors of σ = 2.1 mm and Σ = 1.8 mm, respectively, were reported in the μ direction of the medial tangent beam.…”
Section: Discussionmentioning
confidence: 99%
“…1, bottom pictures). Based on results from a previous study, (7) patients with intent to treat regional nodes including IMCs had only a DIBH CT scan. These patients were treated in FB only if they were unable to perform reproducible DIBH as evaluated by the simulator radiation therapists.…”
Section: A2 Ct Simulationmentioning
confidence: 99%
“…Another approach is the application of respiratory-gated and breath-hold RT, such as deep inspiration breath-hold (DIBH) [1419], which probably allows for a real dose reduction without any increases in low dose areas. Currently, several vendor specific systems are in use: for example the Active Breathing Control (ABC) device designed at William Beaumont Hospital, Michigan [20]; the Varian Real-time Position Management system (RPM TM ) (Varian Medical Systems, Palo Alto, CA, USA [21]), or the AlignRT system of Vision RT Ltd, London, UK, [22].…”
Section: Introductionmentioning
confidence: 99%
“…75 % of all patients were able to reach a Dmean under 1.55 Gy. The NB plans had a Dmean heart of 2.31 Gy (Range 0.71-4.21 Gy), which means that the DIBH-technique could halve the Dmean heart according to literature [16,39,[54][55][56][57][58]. The maximum heart distance (maximal thickness of heart irradiated) was mostly less than 1 cm (Range 0.8-1.2 cm) during irradiation of our DIBH breast cancer cases, mostly less than 2 cm (Range 1.1-3.2 cm) in the NB plans.…”
Section: Dosimetric Outcomesmentioning
confidence: 81%
“…Based on available findings, the DEGRO breast cancer expert panel recommends a Dmean heart dose < 2.5 Gy [55]. Additionally, the study of Yeung et al [39] showed that all patients receiving WBRT (whole breast irradiation) with DIBH met a Dmean heart < 4 Gy and had less heart problems. Remarkably, in our series all patients with DIBH could reach a Dmean heart < 1.2 Gy and almost all patients with NB a Dmean heart < 2.3 Gy which means that our data could comply the DEGRO-recommendations.…”
Section: Discussionmentioning
confidence: 99%