2019
DOI: 10.1109/access.2019.2950798
|View full text |Cite
|
Sign up to set email alerts
|

Cardiotocographic Signal Feature Extraction Through CEEMDAN and Time-Varying Autoregressive Spectral-Based Analysis for Fetal Welfare Assessment

Abstract: Cardiotocograph (CTG) is a widely used tool for fetal surveillance during labor, which provides the joint recording of fetal heart rate (FHR) and uterine contraction data. Unfortunately, the CTG interpretation is difficult because it involves a visual analysis of highly complex signals. Recent clinical research indicates that a correct CTG assessment requires a good understanding of the fetal compensatory mechanisms modulated by the autonomic nervous system. Certainly, this modulation reflects variations in th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 88 publications
0
9
0
Order By: Relevance
“…Moreover, some authors also include in the definition the value of the base excess or base deficit (127). Some authors defined as "at risk of acidemia" when pH < 7.20 (33,47,(128)(129)(130)(131)(132)(133)(134)(135)(136) or pH < 7.15 (30,121,(137)(138)(139)(140)(141)(142)(143); others define when pH < 7.1 (43,126,(144)(145)(146) or even when pH < 7.05 (38,44,48,78,(147)(148)(149)(150)(151)(152)(153)(154)(155)(156)(157)(158)(159)(160)(161)(162)(163)(164)(165)…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, some authors also include in the definition the value of the base excess or base deficit (127). Some authors defined as "at risk of acidemia" when pH < 7.20 (33,47,(128)(129)(130)(131)(132)(133)(134)(135)(136) or pH < 7.15 (30,121,(137)(138)(139)(140)(141)(142)(143); others define when pH < 7.1 (43,126,(144)(145)(146) or even when pH < 7.05 (38,44,48,78,(147)(148)(149)(150)(151)(152)(153)(154)(155)(156)(157)(158)(159)(160)(161)(162)(163)(164)(165)…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, some authors also include in the definition the value of the base excess or base deficit ( 127 ). Some authors defined as “at risk of acidemia” when pH < 7.20 ( 33 , 47 , 128 136 ) or pH < 7.15 ( 30 , 121 , 137 143 ); others define when pH < 7.1 ( 43 , 126 , 144 146 ) or even when pH < 7.05 ( 38 , 44 , 48 , 78 , 147 165 ). Some studies used clinical experts to identify episodes of hypoxia and asphyxia, such as, ( 54 , 166 , 167 ).…”
Section: Resultsmentioning
confidence: 99%
“…It is important to note that in [6,14], the feature extraction strategy slightly differs from the operation performed in this work. In those approaches, we had first computed the indicators (e.g.…”
Section: Resultsmentioning
confidence: 99%
“…The direct calculation method or time-domain windowing can be used to extract the fetal heart rate [ 15 , 16 ]. The signal peak’s positions may drift and any tiny variation in denominator can be amplified.…”
Section: Extraction Of Fetal Heart Ratementioning
confidence: 99%