Case study regarding the thermal environment and energy efficiency of raised-floor and row-based cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…It is the most traditional solution, combined with mechanical refrigeration and terminal of air cooling, for transferring heat generated by IT equipment to the outdoor environment [31]. The traditional solution has the advantages [32] of high reliability, simple maintenance, low operating cost, etc.…”
Section: Traditional Cooling Technologiesmentioning
confidence: 99%
“…It is the most traditional solution, combined with mechanical refrigeration and terminal of air cooling, for transferring heat generated by IT equipment to the outdoor environment [31]. The traditional solution has the advantages [32] of high reliability, simple maintenance, low operating cost, etc.…”
Section: Traditional Cooling Technologiesmentioning
confidence: 99%
“…ANSYS-IcePak software is commonly utilized to simulate the thermal characteristics of data center environment. 3,4 The second step in the CFD simulation involves solving the governing equations (Equations ( 1)-( 9)) for each cell, using finite volume method.…”
Section: The K-ε Turbulent Modelmentioning
confidence: 99%
“…A lot of researchers reported the drawbacks of traditional raised floor cooling architectures including (a) high pressure and temperature drops of cooling air in the raised floor plenum 3 and low supply air flow rate at racks intake, 4 (b) hot air recirculation and cold air bypass, 5 (c) hot spots for the servers placed at low levels of the racks, 6 and (d) un-efficient cooling system due to high losses. 7 Accordingly, a new data center cooling architecture named as in-row cooling architecture has been developed and rapidly sprit.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…They concluded that the cooling effect of the air conditioning units' staggered arrangement in racks could be better than that of aligned arrangement. Jin et al [32] experimentally studied the DC's cooling efficiency under two forms: raised-floor air supply and row-based air conditioning air supply. It was found that the PUE of the DC with row-based air conditioning could decrease by 0.27, compared to the raised-floor supply air.…”
Section: Introductionmentioning
confidence: 99%