Catenary action effects on the structural robustness assessment of RC slab strips subjected to shear and tensile forces

Abstract: Catenary action effects on the structural robustness assessment of RC slab strips subjected to shear and tensile forcesIn this paper, the behaviour of RC slab strips subjected to transverse loads and axial tensile forces is investigated by means of analytical and numerical simulations. The results obtained are compared to the experimental results from tests performed at the Swiss Federal Institute of Technology (ETH). The prediction of the structural response was part of an international benchmark study [1]. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 22 publications
0
8
0
1
Order By: Relevance
“…The representativeness principle can be extended for various structural problems (e.g., References 35 and 54 ), though experimental setups must be verified accordingly. For example, the representativeness of the 80 × 80 × 640 mm prism (Figure c) was improved by increasing the length of the specimen up to 1000 mm.…”
Section: Discussion Of the Resultsmentioning
confidence: 99%
“…The representativeness principle can be extended for various structural problems (e.g., References 35 and 54 ), though experimental setups must be verified accordingly. For example, the representativeness of the 80 × 80 × 640 mm prism (Figure c) was improved by increasing the length of the specimen up to 1000 mm.…”
Section: Discussion Of the Resultsmentioning
confidence: 99%
“…Therefore, the second suggestion 5,14 consists in providing the same reinforcement in the two chords of the beam, making the section symmetrical; • Lateral springs: the presence of the orthogonal structural systems can highly and positively influence the response of the structure when a supporting column collapses, as demonstrated in Refs. [19][20][21][47][48][49][50][51] In general, the horizontal flexural-shear response of the orthogonal beams combined with the slabs can produce "3D effects" with important benefits.…”
Section: Design Suggestions To Improve the Robustnessmentioning
confidence: 99%
“…Reprezentatyvumo principas gali būti išplėstas (pvz., Belletti et al 2016, Caldentey et al 2017, tačiau eksperimentinę sąlygą būtina atitinkamai patikrinti. Pavyzdžiui, 80×80×640 mm prizmės (4.8c pav.)…”
Section: Bandinio Reprezentatyvumo Vertinimasunclassified