2023
DOI: 10.1016/j.ese.2023.100251
|View full text |Cite
|
Sign up to set email alerts
|

Cathodic biofouling control by microbial separators in air-breathing microbial fuel cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 67 publications
1
19
0
Order By: Relevance
“…To reveal how the cathode potential tuned the microbial community composition, high-throughput sequencing was conducted at the end of the stable operation. The coverage values reached more than 0.99, indicating that most of the species had been well sequenced . Compared with the gaps among experimental groups (Bio-OCP, Bio-0.8 V, and Bio-1.0 V), the replicative samples distributed closely according to the principal component analysis (PCA) (Figure S15a), indicating their smaller difference in the microbial community structure.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To reveal how the cathode potential tuned the microbial community composition, high-throughput sequencing was conducted at the end of the stable operation. The coverage values reached more than 0.99, indicating that most of the species had been well sequenced . Compared with the gaps among experimental groups (Bio-OCP, Bio-0.8 V, and Bio-1.0 V), the replicative samples distributed closely according to the principal component analysis (PCA) (Figure S15a), indicating their smaller difference in the microbial community structure.…”
Section: Resultsmentioning
confidence: 99%
“…The coverage values reached more than 0.99, indicating that most of the species had been well sequenced. 33 Compared with the gaps among experimental groups (Bio-OCP, Bio-0.8 V, and Bio-1.0 V), the replicative samples distributed closely according to the principal component analysis (PCA) (Figure S15a), indicating their smaller difference in the microbial community structure. Consistent with this, analysis of similarities (ANOSIM) also revealed smaller differences in the replicative than in experimental groups (R = 0.3004, P = 0.004) (Figure S15b), indicative of a crucial impact of cathodic potential on the microbial community structure.…”
Section: ■ Introductionmentioning
confidence: 99%
“…At the start-up period, the anodes were inoculated with the effluent of MFCs that had been operated for more than half a year. During long-term operation, all reactors were fed with a medium composed of 1.0 g L –1 anhydrous sodium acetate (NaAc), 50 mM PBS, 12.5 mL L –1 trace minerals, and 5 mL L –1 vitamin solutions for more than half a year . During experiments, a stepwise reducing external resistance method (510, 200, and 100 Ω) was applied to culture EBs, and a constant resistor (200 Ω) was used as the external loading for long-term MFC operation.…”
Section: Methodsmentioning
confidence: 99%
“…A new "air cathode and biotic separator" assembly was applied in an air cathode MFC, which largely eliminated biofouling in the cathode and enabled long-term sustainability of the air cathode. 58 Thus, biotic separators undoubtedly go beyond the functions of traditional abiotic separators (Figure 2b).…”
Section: Efficiency and Performance Of Biotic Separators In Mfcs 231 ...mentioning
confidence: 99%
“…Operating techniques, such as biofilm activity regulation, aeration strategy, and hydraulic flow modes, are also accepted for long-term stability. 17,58,145,146 In general, MFC devices have already achieved a low capital cost, a high efficiency, and long-term stability for practical applications.…”
Section: Cost Efficiency and Stability Of Pilot-scale Mfcsmentioning
confidence: 99%