1999
DOI: 10.1038/sj.bmt.1701583
|View full text |Cite
|
Sign up to set email alerts
|

CD34+ cell enumeration in peripheral blood and apheresis samples, using two laboratory diagnostic kits or an institutional protocol

Abstract: Summary:In order to prepare the substitution of a commercially available diagnostic kit, ProCOUNT (Becton Dickinson) or Stem-Kit (Coulter Immunotech), for our institutional protocol, we compared the three techniques for the numeration of CD34 ؉ progenitor cells in 50 peripheral blood and 51 apheresis samples, obtained from cancer patients or healthy donors. We show here that the three techniques yield results of the same order of magnitude. Although statistical analyses demonstrate significant differences betw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
13
0

Year Published

2000
2000
2021
2021

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 19 publications
1
13
0
Order By: Relevance
“…The use of the BDIS ProCount kit was shown to reduce remarkably both the intralaboratory and interlaboratory assay variability (60,178,179). The same was demonstrated for the Beckman-Coulter StemKit assay in a singlecenter study (179).…”
Section: Multicenter Studies On Cd34؉ Cell Counting: the Emerging Conmentioning
confidence: 75%
“…The use of the BDIS ProCount kit was shown to reduce remarkably both the intralaboratory and interlaboratory assay variability (60,178,179). The same was demonstrated for the Beckman-Coulter StemKit assay in a singlecenter study (179).…”
Section: Multicenter Studies On Cd34؉ Cell Counting: the Emerging Conmentioning
confidence: 75%
“…This commercially available diagnostic kit includes the viability dye 7-amino actinomycin D (7-AAD), that allows for a quantitation of viable CD34 þ and CD45 þ cells. 22 Absolute lymphocyte counts were determined using the Multitest kit (Becton Dickinson Immunocytometry Systems, San Jose, CA, USA). This commercially available diagnostic kit allows for a quantitation of 23 Data acquisitions and analyses were performed on a FACSCalibur four-color flow cytometer using the Cellquest and Multiset softwares (Becton Dickinson Immunocytometry System, BDIS, San Jose, CA, USA).…”
Section: Thawing Proceduresmentioning
confidence: 99%
“…Absolute counts of CD34 + cells were determined, using the Stem-Kit numeration kit (Beckman-Coulter/Immunotech, Hialeah, FL, USA), 23 according to the manufacturer's instructions. This commercially available diagnostic kit includes the viability dye 7-amino actinomycin D (7-AAD) that allows for a quantitation of both viable and nonviable CD34 + cells.…”
Section: Flow Cytometry Analysesmentioning
confidence: 99%