2021
DOI: 10.1016/j.mtchem.2021.100615
|View full text |Cite
|
Sign up to set email alerts
|

Cellulose-based fluorescent macromolecular sensors and their ability in 2, 4, 6-trinitrophenol detection

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…We have previously stated that some naphthalimides have been used for detection of trinitrophenol (TNP), an environmental contaminant and potential explosive, [52][53] therefore we wanted to study the performance of the fluorescent probe in the detection of TNP, in comparison to the detection of TNT and TNB. As in previous cases, a study of the behaviour of AR85 in the presence of excess TNP in different solvents was performed (Supp.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…We have previously stated that some naphthalimides have been used for detection of trinitrophenol (TNP), an environmental contaminant and potential explosive, [52][53] therefore we wanted to study the performance of the fluorescent probe in the detection of TNP, in comparison to the detection of TNT and TNB. As in previous cases, a study of the behaviour of AR85 in the presence of excess TNP in different solvents was performed (Supp.…”
Section: Resultsmentioning
confidence: 99%
“…The obtained LODs compete favorably with those obtained in previously known examples. [52][53] Then we were curious about the possibility of detecting one explosive taggant, such as 2,4-dinitrotoluene (DNT), [70] or the most common nitrobenzene (NB). In both cases we got related titration curves and titration profiles (Supp.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescence-based sensing methods stand out among various techniques due to their simplicity, high sensitivity, affordability, straightforward sample preparation, and portability, offering immense potential. 7 Lots of uorescent sensors have been constructed to detect PA. [8][9][10] A donor-acceptor conjugated polymer based on diethylamine phenyl and benzothiadiazole groups was fabricated to detect PA with a K sv constant of 1.8 × 10 3 M −1 . 11 Hyperbranched conjugated polymers (HCPs) were rst synthesized using truxene and diethynylbenzene derivates, which were carried by F127 in water to form highly uorescent HCP micelles.…”
Section: Introductionmentioning
confidence: 99%