1989
DOI: 10.1097/00003086-198912000-00003
|View full text |Cite
|
Sign up to set email alerts
|

Cementless Press-Fit Cup Principles, Experimental Data, and Three-Year Follow-Up Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
16
0
1

Year Published

1992
1992
2011
2011

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 48 publications
(18 citation statements)
references
References 0 publications
1
16
0
1
Order By: Relevance
“…Axial forces and displacement were 586b / 8h15$$586b 07-14-98 12:04:51 jbma W-JBM in metal backed models, which ranged from 3.2 to 6.3 MPa. 30,31 Also, interfacial tensile strength of the best osteointegrated interface between the porous metal surface and bone is about the same order of magnitude as the maximum strength observed in this study. 49 The relative amount of the chemical bonding and mechanical interdigitation between the PMMA layer and the UHMWPE surface are not directly quantified at this time, but they are in progress in the form of chemical analyses by ATR-FTIR and ESCA on tomographically sectioned surface layers.…”
Section: Methodssupporting
confidence: 75%
See 3 more Smart Citations
“…Axial forces and displacement were 586b / 8h15$$586b 07-14-98 12:04:51 jbma W-JBM in metal backed models, which ranged from 3.2 to 6.3 MPa. 30,31 Also, interfacial tensile strength of the best osteointegrated interface between the porous metal surface and bone is about the same order of magnitude as the maximum strength observed in this study. 49 The relative amount of the chemical bonding and mechanical interdigitation between the PMMA layer and the UHMWPE surface are not directly quantified at this time, but they are in progress in the form of chemical analyses by ATR-FTIR and ESCA on tomographically sectioned surface layers.…”
Section: Methodssupporting
confidence: 75%
“…Thus, value of 6.3 MPa between UHMWPE and titanium, it is quite significant. 30 Among samples of 60 min, 20 and 40% even at a lower temperature of 100 ЊC, the solution with higher monomer concentration can possibly prevent further (v/v) monomer concentrations showed slightly low tensile strength values of 8.73 and 11.32 MPa, respectively, with MMA diffusion as the treatment time increases. This trend can also be observed from Figure 5 where samples under no statistically significant differences from that of the 50%-60-min sample.…”
Section: Methodsmentioning
confidence: 91%
See 2 more Smart Citations
“…The contralateral side was identical to the uncoated implants. This implant modification was chosen because of its similarity to clinically used implants [12,13].…”
Section: Methodsmentioning
confidence: 99%