1997
DOI: 10.1002/elps.1150180613
|View full text |Cite
|
Sign up to set email alerts
|

Central composite design in the chiral analysis of amphetamines by capillary electrophoresis

Abstract: We have studied a central composite design for the chiral separation of amphetamines using capillary electrophoresis. Five variables, i.e., buffer concentration, pH, chiral selector concentration, temperature, and applied voltage, were investigated. Enantiomeric resolutions as well as analysis time and generated power were established as responses for each experiment. A model of each response was obtained by multiple regression of a quadratic-degree mathematical expression. From the models, we determined the m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
31
0
2

Year Published

1998
1998
2013
2013

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 68 publications
(33 citation statements)
references
References 42 publications
0
31
0
2
Order By: Relevance
“…2B). As already demonstrated CZE, 36,37 HP-b-CD is the best chiral in selector for the separation of amphetamines. In UHPLC, a concentration of 20 mM HP-b-CD was chosen as the best compromise between enantioselectivity and backpressure for all tested compounds.…”
Section: Direct Chromatographic Separation Using a Chiral Mobile Phasmentioning
confidence: 60%
“…2B). As already demonstrated CZE, 36,37 HP-b-CD is the best chiral in selector for the separation of amphetamines. In UHPLC, a concentration of 20 mM HP-b-CD was chosen as the best compromise between enantioselectivity and backpressure for all tested compounds.…”
Section: Direct Chromatographic Separation Using a Chiral Mobile Phasmentioning
confidence: 60%
“…As the natural factor levels at treatments no. 17 to 25 had not been chosen properly in the experiment reported in [5], coded levels of x 2 to x 4 in these rows differ from the standard design described in the fundamental books [10,11,12] or in papers [13,14,15,16,17]. This fact may have some minor effect to the precision of predictions.…”
Section: Experimental Variablesmentioning
confidence: 99%
“…Le rôle de TEC dans la détermination des formes énantiomèriques devient prépondérant (20,45,60). Lurie (60) étudie l'effet de sélecteurs chiraux anioniques sur la CEC d'un mélange chirat de phénylé-thylamines et d'impuretés neutres non chirales présents dans de la méthamphétamine illicite.…”
Section: -Analyse De Substances Illicites Saisiesunclassified
“…L'équipe de Thormann est certainement encore la plus active dans l'analyse des milieux biologiques (10-12) et il décrit dans une revue de la littérature sur les années 1997 et 1998 les progrès récents de TEC et les applications en routine en toxicologie clinique et médico-légale. Des études plus spécifiques se développent : TEC est en train de devenir l'approche la plus commune pour l'analyse chirale de nombreux médicaments et substances illicites (13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25) (28). Cependant, l'injection directe de l'échantillon reste peu appliquée à l'analyse toxicologique de prélè-vements biologiques en raison de la faible concentration des xénobiotiques.…”
Section: -Introductionunclassified