2012
DOI: 10.1139/h2012-109
|View full text |Cite
|
Sign up to set email alerts
|

Central hemodynamic responses during acute high-intensity interval exercise and moderate continuous exercise in patients with heart failure

Abstract: The aim of this study was to compare the acute hemodynamic responses during high-intensity intermittent exercise (HIIE) session compared with moderate-intensity continuous exercise (MICE) session in patients with heart failure and reduced ejection fraction (HFREF). Thirteen patients with HFREF (age, 59 ± 6 years; left ventricular ejection fraction, 27% ± 6%; New York Heart Association class I to III) were randomly assigned to a single session of HIIE (2 × 8 min) corresponding to 30 s at 100% of peak power outp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

5
34
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 30 publications
(40 citation statements)
references
References 23 publications
5
34
1
Order By: Relevance
“…Calibration of the Cosmed flow module was accomplished by introducing a calibrated volume of air at several flow rates with a 3-liter pump. 13 Gas analyzers were calibrated before each test using a standard certified commercial gas preparation (O 2 : 16%; CO 2 : 5%) according to manufacturer's specifications and previous published methodology. 1,13 Data were measured every four respiratory cycles during testing and then were averaged every 15 s for minute ventilation (VE, in L min −1 BTPS), oxygen uptake (VO 2 , in L min −1 , STPD), carbon dioxide production (VCO 2 , in L min −1 STPD).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Calibration of the Cosmed flow module was accomplished by introducing a calibrated volume of air at several flow rates with a 3-liter pump. 13 Gas analyzers were calibrated before each test using a standard certified commercial gas preparation (O 2 : 16%; CO 2 : 5%) according to manufacturer's specifications and previous published methodology. 1,13 Data were measured every four respiratory cycles during testing and then were averaged every 15 s for minute ventilation (VE, in L min −1 BTPS), oxygen uptake (VO 2 , in L min −1 , STPD), carbon dioxide production (VCO 2 , in L min −1 STPD).…”
Section: Methodsmentioning
confidence: 99%
“…13 Gas analyzers were calibrated before each test using a standard certified commercial gas preparation (O 2 : 16%; CO 2 : 5%) according to manufacturer's specifications and previous published methodology. 1,13 Data were measured every four respiratory cycles during testing and then were averaged every 15 s for minute ventilation (VE, in L min −1 BTPS), oxygen uptake (VO 2 , in L min −1 , STPD), carbon dioxide production (VCO 2 , in L min −1 STPD). 1 Maximal exercise tests on IE and DE lasted until the attainment of one of the two primary maximal criteria: (1) a plateau ofVE despite an increase in cadence, (2) R.E.R.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations