2016
DOI: 10.4172/2327-5146.1000228
|View full text |Cite
|
Sign up to set email alerts
|

Central Venous Pressure as a Predictor of Fluid Responsiveness: Is This All You Need?

Abstract: Fluid administration during and after surgery is a fundamental strategy for maintaining hemodynamic stability. Technology offers different strategies for hemodynamic monitoring and decision making about fluids administration. In particular patients may be divided into fluid-responding patients and non-fluid-responding patients. Central venous pressure, measured by a central venous catheter, is a basic measure of right heart preload, and many trials defined it as a non-trustable parameter, with many biases and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 13 publications
0
2
0
1
Order By: Relevance
“…21 Tekanan vena sentral yang tinggi dapat ditemukan pada penderita dengan fungsi jantung yang normal dan volume intravaskular meningkat (misalnya overload cairan) atau pada penderita dengan fungsi jantung yang menurun dan volume intravaskular normal (misalnya gagal jantung). 22 Sebaliknya, CVP dapat turun pada individu dengan fungsi jantung meningkat dan volume darah normal (misalnya selama olahraga) atau pada penderita dengan fungsi jantung normal dan volume darah menurun (misalnya kehilangan darah berat), diuresis yang berlebihan akibat diabetes atau terapi diuretik, atau venous return yang buruk pada syok kardiogenik. 21 Baku emas evaluasi respons penderita terhadap terapi cairan adalah respons hemodinamik terhadap fluid challenge.…”
Section: Tekanan Vena Sentral (Central Venous Pressure/cvp)unclassified
“…21 Tekanan vena sentral yang tinggi dapat ditemukan pada penderita dengan fungsi jantung yang normal dan volume intravaskular meningkat (misalnya overload cairan) atau pada penderita dengan fungsi jantung yang menurun dan volume intravaskular normal (misalnya gagal jantung). 22 Sebaliknya, CVP dapat turun pada individu dengan fungsi jantung meningkat dan volume darah normal (misalnya selama olahraga) atau pada penderita dengan fungsi jantung normal dan volume darah menurun (misalnya kehilangan darah berat), diuresis yang berlebihan akibat diabetes atau terapi diuretik, atau venous return yang buruk pada syok kardiogenik. 21 Baku emas evaluasi respons penderita terhadap terapi cairan adalah respons hemodinamik terhadap fluid challenge.…”
Section: Tekanan Vena Sentral (Central Venous Pressure/cvp)unclassified
“…Central venous pressure (CVP) is a hemodynamic parameter that has widely been monitored in the intensive care units (ICU) for assessing the cardiac function, the right atrium preload, the volume status and the fluid responsiveness in critically ill patients [1][2][3]. Over the course of time the usefulness and the accuracy of CVP as a strong hemodynamic and endovascular volume index has been debated and the currently available published research reveals no absolute correlation between CVP values and the total blood volume present in human circulation [4].…”
Section: Introductionmentioning
confidence: 99%
“…Central venous pressure (CVP) is a hemodynamic parameter that has widely been monitored in the intensive care units (ICU) for assessing cardiac function, the right atrium preload, the volume status, the fluid responsiveness in critically ill patients, and it is defined as the estimated pressure in the vena cava, so can be considered as a measurement of cardiac preload and right atrial pressure [1][2][3]. The normal range of CVP, that is measured in a supine position via a central venous catheter placed into the subclavian or internal jugular vein, is inconsistent with different depicted values, such as 2-8 mmHg [4], 0-10 mmHg [5], or 5-15 mmHg [6], available in the currently available published research.…”
Section: Introductionmentioning
confidence: 99%