2022
DOI: 10.1016/j.actbio.2021.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Centrifugally concentric ring-patterned drug-loaded polymeric coating as an intraocular lens surface modification for efficient prevention of posterior capsular opacification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
34
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 28 publications
(35 citation statements)
references
References 63 publications
1
34
0
Order By: Relevance
“…This irregular and dispersed hierarchical nanostructure contributed to the highly specific surface areas and enhanced diffuse reflection, thus generating photothermal conversion with high efficiency. As optical characteristics are critical for visual recovery after IOL implantation, [ 23 ] we examined the spatial resolution efficiency of R‐IOL and P‐IOL based on the 1951 version of the United States Air Force (USAF) resolution board standard (Figures 2c and S1b, Supporting Information). No significant differences were noted between R‐IOL and P‐IOL, demonstrating that NPG modification did not cause differences in the spatial resolution of the optical center area.…”
Section: Resultsmentioning
confidence: 99%
“…This irregular and dispersed hierarchical nanostructure contributed to the highly specific surface areas and enhanced diffuse reflection, thus generating photothermal conversion with high efficiency. As optical characteristics are critical for visual recovery after IOL implantation, [ 23 ] we examined the spatial resolution efficiency of R‐IOL and P‐IOL based on the 1951 version of the United States Air Force (USAF) resolution board standard (Figures 2c and S1b, Supporting Information). No significant differences were noted between R‐IOL and P‐IOL, demonstrating that NPG modification did not cause differences in the spatial resolution of the optical center area.…”
Section: Resultsmentioning
confidence: 99%
“…PLGA can effectively protect drugs from degradation and unrestrained release. Solutions of PLGA and cyclosporine A (CsA) were used to modify the IOL surface by Lu et al (2022) . The spin coating method was applied to construct the centrifuging concentric circles drug-loaded coating on the IOL surface.…”
Section: Intraocular Lens Surface Modification Materialsmentioning
confidence: 99%
“…For example, the CsA-loaded PLGA (CsA@PLGA) coating-modified IOL prepared by Teng et al [ 103 ] reduced the degree of PCO within six months after implantation in rabbit models. Using the spin-coating technique, Lu et al [ 104 ] designed and fabricated a centrifugally concentric ring-patterned drug-loaded PLGA coating ( Figure 8 ). The concentric ring morphology, drug loading, and release properties were investigated, and the spin-coating parameters were optimized.…”
Section: The Main Types Of Iols Used For Pco Prophylaxismentioning
confidence: 99%