2012
DOI: 10.3109/02713683.2011.635399
|View full text |Cite
|
Sign up to set email alerts
|

Changes in Anterior Chamber Parameters with the Pentacam Rotating Scheimpflug and Axial Length Measurements by Ultrasound in Patients Who Use Isotretinoin

Abstract: Isotretinoin treatment causes statistically significant changes in most anterior segment parameters during treatment.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 13 publications
0
10
0
Order By: Relevance
“…Anterior segment reconstructions were produced with 25 single captures in this study. After completing a scan, the Pentacam software constructs a three-dimensional image of the anterior segment and calculates the ante rior chamber parameters (9) . This imaging provides measurements of anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, and pupil size.…”
Section: Patient Assessmentmentioning
confidence: 99%
“…Anterior segment reconstructions were produced with 25 single captures in this study. After completing a scan, the Pentacam software constructs a three-dimensional image of the anterior segment and calculates the ante rior chamber parameters (9) . This imaging provides measurements of anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, and pupil size.…”
Section: Patient Assessmentmentioning
confidence: 99%
“…We found a statistically significant increase for only average SimK values and SAIs between the baseline and the first month of isotretinoin treatment with the use of Sirius. Cumurcu et al recorded significant changes in mean keratometry values between baseline and after the 3rd and 6th months of therapy by means of Pentacam [ 11 ]. The increase in keratometry readings of cornea should be considered when calculating the intraocular lens power for patients at early stages of isotretinoin therapy.…”
Section: Discussionmentioning
confidence: 99%
“…We found a significant reduction in the thinnest corneal thickness measured with Sirius between the baseline and the 1st, 3rd, and 6th months of isotretinoin treatment. Similarly, Cumurcu et al found a significant difference between pretreatment values and the 3rd and 6th month values for CCT, as measured with a Pentacam rotating Scheimpflug, in patients treated with isotretinoin [ 11 ]. A value of residual stromal bed thickness below 250 μ m is considered to be a major risk factor for the development of iatrogenic keratectasia in corneal refractive surgery [ 12 ].…”
Section: Discussionmentioning
confidence: 99%
“…Pentacam is based on a 180° rotating Scheimpflug camera which can take 12–50 single images to reconstruct the anterior chamber. After completing test, Pentacam software constructs a three-dimensional image of the anterior segment and calculates the anterior chamber parameters [9]. Three measurements were taken from each case by Pentacam.…”
Section: Methodsmentioning
confidence: 99%