1997
DOI: 10.1016/s0009-9120(96)00132-4
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of a 20-minute whole blood rapid assay for cardiac troponin T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1998
1998
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…The chip consisted of two distinct flow channels in the vertical and horizontal directions (Figure A). The vertical compartment was carved to tightly fit a 2-mm-wide immunostrip, essentially the same as that of a conventional rapid test kit, , except it also used an enzyme tracer (e.g., HRP). A sample application pot and a signal monitoring window were installed by drilling through the chip surfaces.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The chip consisted of two distinct flow channels in the vertical and horizontal directions (Figure A). The vertical compartment was carved to tightly fit a 2-mm-wide immunostrip, essentially the same as that of a conventional rapid test kit, , except it also used an enzyme tracer (e.g., HRP). A sample application pot and a signal monitoring window were installed by drilling through the chip surfaces.…”
Section: Resultsmentioning
confidence: 99%
“…Two membrane components, the immunostrip and the horizontal flow absorption pad, were prepared for installation into the chip (Figure B). The immunostrip was composed of four different, commercially available membranes, furnishing various functions of sample application, enzyme conjugate release, signal generation, and vertical flow absorption. , They were lengthily disposed in order, partially superimposed on one another, and mounted on a plastic film. This strip was fixed in the vertical channel of the chip.…”
Section: Resultsmentioning
confidence: 99%
“…The cTnT RAl has been tested in suspected MI patients and was found to be appropriate for diagnosing MI. 4 ,19.20 Christenson et al 18 further examined the RAI device in a more diverse group and characterized its performance compared to a quantitative cTnT assay at a cut-off of 0•2 /lg/L.…”
Section: Discussionmentioning
confidence: 99%
“…The goal of POC testing, if implemented, should be to improve patient outcomes. 21,22 Certain assays such as whole-blood lactate 7 and myocardial injury markers, [23][24][25] recently developed for qualitative POC testing for cardiac troponin T and troponin I, appear to have a role in acute care medicine and seem to be useful when performed near the patient. Additionally, a test cluster consisting of quantitative myoglobin, creatine kinase-MB mass, and troponin I is clinically efficient, 26 and current literature supports rapid turnaround time for myocardial injury markers.…”
Section: Potential Advantages and Disadvantagesmentioning
confidence: 99%