2016
DOI: 10.1088/1748-0221/11/12/c12005
|View full text |Cite
|
Sign up to set email alerts
|

Characterization and simulation of fast neutron detectors based on surface-barrier VPE GaAs structures with polyethylene converter

Abstract: A: Fast neutron detectors with an active area of 80 mm 2 based on surface-barrier VPE GaAs structures were fabricated and tested. Polyethylene with density of 0.90 g/cm 3 was used as a converter layer. The recoil-proton surface-barrier sensor was fabricated on high purity VPE GaAs epilayers with a thickness of 50 µm. The neutron detection efficiency measured with a 241 Am-Be source was 1.30 • 10 −3 puls./neutr. for the PE converter thickness of 670 µm. The signal-togamma-background ratio was at the level of 50… Show more