2023
DOI: 10.1016/j.radphyschem.2022.110507
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of a Compton camera based on the TOFPET2 ASIC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 40 publications
0
5
0
Order By: Relevance
“…These values represent an enhancement compared to the 5.6 and 6.6% of its predecessor (Barrientos et al, 2021). These results were also superior to other CCs based on SiPMs for different approaches, such as hadron therapy treatment monitoring with MACACOp (6.6% and 6.4% FWHM at 511 keV) (Viegas et al, 2022) or Compton-PET applications (8.3% FWHM at 511 keV) (Takyu et al, 2021). The SiPM characterization at controlled temperatures indicates that the new detectors provide a three times reduction in the effect of temperature fluctuations compared to the 50 μm model (Solevi Barrio et al, 2018).…”
Section: Discussionmentioning
confidence: 70%
See 2 more Smart Citations
“…These values represent an enhancement compared to the 5.6 and 6.6% of its predecessor (Barrientos et al, 2021). These results were also superior to other CCs based on SiPMs for different approaches, such as hadron therapy treatment monitoring with MACACOp (6.6% and 6.4% FWHM at 511 keV) (Viegas et al, 2022) or Compton-PET applications (8.3% FWHM at 511 keV) (Takyu et al, 2021). The SiPM characterization at controlled temperatures indicates that the new detectors provide a three times reduction in the effect of temperature fluctuations compared to the 50 μm model (Solevi Barrio et al, 2018).…”
Section: Discussionmentioning
confidence: 70%
“…The reported CTR value indicates that there is room for improvement in terms of timing resolution. In addition to time-walk correction strategies, an alternative prototype known as MACACOp using TOF-PET2 ASIC (PETSyS) is under evaluation with the aim of improving this parameter (Viegas et al, 2022).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The MACACO II prototype was composed of two identical detector modules. Each one consisted of a 25.8 × 25.8 × 5 mm 3 LaBr 3 monolithic scintillation crystal [43]. Different multi-slit prompt gamma cameras were developed.…”
Section: Introductionmentioning
confidence: 99%
“…Time resolution is a limitation in MACACO III-with 50 ns TCW reported in Barrientos et al (2021) and a timing resolution of 24 ns FWHM-. This is the reason why an alternative prototype, named MACACOp, is being developed in parallel, with TOFPET2 ASIC as readout electronics, with 1.50 ns FWHM and a TCW of 10 ns (Viegas et al 2023). Results in in-beam tests carried out by MACACOp have been also presented in Viegas et al (2023).…”
Section: Introductionmentioning
confidence: 99%