2002
DOI: 10.1109/tns.2002.1039661
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of an integrated sensor using optically stimulated luminescence for in-flight dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2005
2005
2011
2011

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 9 publications
0
5
0
1
Order By: Relevance
“…The OSL reader used in this work is an infrared LED focused on the irradiated specimen that is positioned in a samples holder in a light-tight box. The emitted luminescent signal is collected by means of a photomultiplier, then digitalized and recorded by a PC connected to the test bench via a RS-232 interface [7], [9].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The OSL reader used in this work is an infrared LED focused on the irradiated specimen that is positioned in a samples holder in a light-tight box. The emitted luminescent signal is collected by means of a photomultiplier, then digitalized and recorded by a PC connected to the test bench via a RS-232 interface [7], [9].…”
Section: Resultsmentioning
confidence: 99%
“…OSL materials as radiation dosimeters for medical and space applications have been studied extensively [7], [8] High-Energy Physics (HEP) applications, successful experiments were carried out to measure the dose delivered by different charged particles [9]. Since there is a lack of on-line neutron dosimeters for HEP applications, especially for thermal neutron energies, the possibility to make OSL material sensitive to neutrons is a very attractive prospect.…”
Section: Introductionmentioning
confidence: 99%
“…After beam exposure, the OSL exhibits a visible emission spectrum when stimulated with near infrared light [16], [17]. The OSL foil reader is a solid-state laser beam (of about 1.0 m wave length) focused on the irradiated foil that is positioned on a X-Y stage [18].…”
Section: Optically Stimulated Luminescent Materialsmentioning
confidence: 99%
“…La faisabilité d'un système de dosimétrie en ligne a aussi été démontrée Dusseau, 2000). Ravotti et al, 2004 ;Vaillé et al, 2005Vaillé et al, , 2003Vaillé, 2003 ;Plattard et al, 2002 ;Dusseau et al, 2000) Les premières missions expérimentales telles que le satellite MPTB de la NASA, ou le module ICARE du CNES, spécialement dédiées à l'étude de l'environnement radiatif, ont mis en évidence le caractère dynamique de l'environnement radiatif spatial (Tab. III).…”
Section: La Cartographie De Dose Osl Et Ses Applicationsunclassified