2010
DOI: 10.1088/0953-4075/43/14/144015
|View full text |Cite
|
Sign up to set email alerts
|

Charge exchange recombination spectroscopy on a diagnostic hydrogen beam—measuring impurity rotation and radial electric field at the tokamak TEXTOR

Abstract: To cite this version:J W Coenen, M Clever, U Samm, O Schmitz, B Schweer, et al.. Charge exchange recombination spectroscopy on a diagnostic hydrogen beammeasuring impurity rotation and radial electric field at the tokamak TEXTOR. Journal of Physics B: Atomic, Molecular and Optical Physics, IOP Publishing, 2010, 43 (14) Abstract. In this work we present an overview on the CXRS diagnostic operated with the modulated diagnostic hydrogen beam at the Tokamak TEXTOR. The diagnostic setup combines two observation sy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
18
0
2

Year Published

2010
2010
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 18 publications
(22 citation statements)
references
References 40 publications
2
18
0
2
Order By: Relevance
“…The phase velocity can now be calculated from the mode velocity, given by the measured f/n values and the poloidal part of the E × B velocity v p,E×B (r) = E(r)× Bt(r) Bt(r) 2 via Equation 4, where the radial electric field E is measured with the charge exchange recombination spectroscopy (CXRS) diagnostic [18,19]. Conversely, the mode can be localized with this equation if the phase velocity is known.…”
Section: Phase IIImentioning
confidence: 99%
“…The phase velocity can now be calculated from the mode velocity, given by the measured f/n values and the poloidal part of the E × B velocity v p,E×B (r) = E(r)× Bt(r) Bt(r) 2 via Equation 4, where the radial electric field E is measured with the charge exchange recombination spectroscopy (CXRS) diagnostic [18,19]. Conversely, the mode can be localized with this equation if the phase velocity is known.…”
Section: Phase IIImentioning
confidence: 99%
“…Furthermore, information on angular or energy distribution is conserved, as collisional quenching of excited levels by electrons or ions remains inefficient. Spectroscopic observations in the present experiments were obtained from two spectrometers previously installed at the tokamak TEXTOR [28]. The highresolution instrument utilises Echelle grating in a highorder (≈ 40) Littrow configuration with a dispersion of about 0.7-1.0Å/mm, a focal length of 1000 mm, groove density of 79 grooves/mm and a blaze angle of 76 • .…”
Section: Experimental Set-upmentioning
confidence: 99%
“…К числу наиболее важных параметров, требующих детального и надёжного измерения в условиях современных токамаков и будущего токамака-реактора, относятся такие параметры, как величина и профиль ионной температуры Ti(r), скорости вращения шнура, а также концентрации ядер примесей nZ(r) в плазме. Базовой диагностикой, позволяющей обеспечить локальные измерения этих параметров в условиях токамака, является CXRS-диагностика (Charge eXchange Recombination Spectroscopy), развитая на Т-10 [1], а также на многих других плазменных установках [2][3][4][5][6].…”
Section: Introductionunclassified