2023
DOI: 10.1039/d2cc06341g
|View full text |Cite
|
Sign up to set email alerts
|

Charge transport of F4TCNQ with different electronic states in single-molecule junctions

Abstract: The molecular conductance of 2,3,5,6-tetrafluoro-7,7,8,8,-tetracyano-quinodimethane (F4TCNQ) with different electronic states (neutral, radical anion, and dianion) were investigated by scanning tunneling microscope break junction (STM-BJ) technique. These electronic states have distinct...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 50 publications
0
3
0
Order By: Relevance
“…The target fluorine-substituted arenes were synthesized via reported methods. First, the molecular conductance of S2 and S3 (for chemical structures, see Figures d,e and S1) was measured with the scanning tunneling microscope-based break junction (STM-BJ) technique under 400 mV. As shown in Figure a, conductance plateaus are observed in the individual conductance traces of S2 and S3 . The logarithmically binned 1D conductance histograms of S2 and S3 display obvious conductance signals located at 10 –3.44 G 0 and 10 –5.56 G 0 , respectively (Figure b).…”
Section: Resultsmentioning
confidence: 99%
“…The target fluorine-substituted arenes were synthesized via reported methods. First, the molecular conductance of S2 and S3 (for chemical structures, see Figures d,e and S1) was measured with the scanning tunneling microscope-based break junction (STM-BJ) technique under 400 mV. As shown in Figure a, conductance plateaus are observed in the individual conductance traces of S2 and S3 . The logarithmically binned 1D conductance histograms of S2 and S3 display obvious conductance signals located at 10 –3.44 G 0 and 10 –5.56 G 0 , respectively (Figure b).…”
Section: Resultsmentioning
confidence: 99%
“…During measurements, we collected more than 3000 single traces to ensure the data reliability. [32][33][34][35][36] These traces were further used to plot 2D and 1D conductance histograms. As shown in Fig.…”
mentioning
confidence: 99%
“…The conductance measurement was conducted according to the reported works in our group. 12,[23][24][25][26][27] To ensure the conductance is reproducible statistically, 2000 single conductance-displacement traces were collected for each sample. The traces are used to depict the one-dimensional (1D) conductance histograms and two-dimensional (2D) conductancedisplacement histograms.…”
mentioning
confidence: 99%