2022
DOI: 10.1016/j.scijus.2022.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Chemical trace XRF analysis to detect sharp force trauma in fresh and burned bone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…Interference in the X-ray peak in the spectrum can be easily corrected, thus ensuring high accuracy and sensitivity easily. EDXRF and wavelength-dispersive XRF spectroscopy are used for qualitative and quantitative multi-element analysis of major, minor, and trace elements in archeological, geological, biological, industrial, food, and environmental samples and require minimal sample preparation. , The analysis of PTEs in the bentonite samples was performed with the help of the EDXRF spectrometer (Spectro Xepos, Ametek). The EDXRF spectrometer is equipped with an anode X-ray tube (50 W, 60 kV) consisting of a dual thick Pd/Co mixture. ,,,, The EDXRF spectrometer’s target modifier, which optimizes excitation by using polarization and secondary targets, has many different excitation conditions that guarantee the best detection of all elements from Na to U.…”
Section: Methodsmentioning
confidence: 99%
“…Interference in the X-ray peak in the spectrum can be easily corrected, thus ensuring high accuracy and sensitivity easily. EDXRF and wavelength-dispersive XRF spectroscopy are used for qualitative and quantitative multi-element analysis of major, minor, and trace elements in archeological, geological, biological, industrial, food, and environmental samples and require minimal sample preparation. , The analysis of PTEs in the bentonite samples was performed with the help of the EDXRF spectrometer (Spectro Xepos, Ametek). The EDXRF spectrometer is equipped with an anode X-ray tube (50 W, 60 kV) consisting of a dual thick Pd/Co mixture. ,,,, The EDXRF spectrometer’s target modifier, which optimizes excitation by using polarization and secondary targets, has many different excitation conditions that guarantee the best detection of all elements from Na to U.…”
Section: Methodsmentioning
confidence: 99%
“…Previous research on the identification and analysis of copper cable matrices due to overheating has been widely carried out, including analyzing the electrical conductor surface of copper cables using Sem, microstructure and mechanical properties of the wire also on Cu-Al using SEM [12], the influence of process parameters on surface quality and copper bond quality also with SEMEDS [13], investigation of Cu-P structure by overheating [14], which is based on the cable surface morphology. Meanwhile, surface analysis with XRF was previously also carried out for chemical trace analysis to detect sharp force trauma in fresh conditions and burnt bones [15], investigation of the impact of autoclave curing on the mechanical properties, heavy metal stabilization, and anti-microbial activity of green geopolymer composites [16].…”
Section: Introductionmentioning
confidence: 99%