Chemiluminescence Sensor for the Determination of Perphenazine Based on a Molecular Imprinted Polymer

Abstract: Experimental ApparatusThe schematic diagram of the sensor used in this work is shown in Fig. 1. The reagent solutions and sample solutions were delivered with two peristaltic pumps. PTFE tubes (0.8 mm i.d.) were used to connect all components in the flow system. CL measurements were performed using an IFFL-D CL analyzer (Xi'an Remax Electronic High-Tech Ltd., China). A luminol-potassium ferricyanide-perphenazine CL reaction with high sensitivity for the determination of perphenazine was found. A perphenazine m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…23 CL systems have also been used for the determination of perphenazine. These methods are based on the CL systems including permanganate in sulphuric acid, 24 luminalKMnO 4 , 25 luminal-ferricyanide 26,27 and Ce(IV)-HNO 3 . 28 In experimentation, we attempt to monitor the effects of certain inputs or material on the subject matter of interest.…”
Section: +mentioning
confidence: 99%
See 1 more Smart Citation
“…23 CL systems have also been used for the determination of perphenazine. These methods are based on the CL systems including permanganate in sulphuric acid, 24 luminalKMnO 4 , 25 luminal-ferricyanide 26,27 and Ce(IV)-HNO 3 . 28 In experimentation, we attempt to monitor the effects of certain inputs or material on the subject matter of interest.…”
Section: +mentioning
confidence: 99%
“…In comparison with CL methods, [24][25][26]28 the proposed method is sensitive with a wide linear dynamic range, moreover it has been applied for the quantification of perphenazine in human serum and pharmaceuticals. Some of the sensitive methods in Table 8, besides chemical information for perphenazine, provide multianalyte information about related species, compounds and metabolites presented in the sample.…”
Section: Response Characteristicsmentioning
confidence: 99%
“…For comparison with the present sensor, several related methods are listed in Table 3. As shown in Table 3, the two MIP based flowinjection CL sensors required special instruments, [19,20] and the preparation of the MIP-based potentiometric sensor was sophiscated. [26] Furthermore, the three sensors were only able to detect the samples one by one, and their sensitivities were much lower than the present sensor.…”
Section: Comparison With Related Methodsmentioning
confidence: 99%
“…In this method, the co‐existed interferents can be eliminated by the MIP effectively, so the method selectivity is highly improved. Therefore, the MIP‐CL method has been used to analyze many analytes, including PZs …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation