2010
DOI: 10.1021/ac100131e
|View full text |Cite
|
Sign up to set email alerts
|

Chip-based Reversed-phase Liquid Chromatography−Mass Spectrometry of Permethylated N-Linked Glycans: A Potential Methodology for Cancer-biomarker Discovery

Abstract: The study of protein glycosylation in biological fluids and tissues has substantial medical importance, as changes in glycan structures have now been associated with a number of diseases. Quantification of glycomic-profile changes is becoming increasingly important in the search for disease biomarkers. Here, we report a highly reproducible combination of a glycomic sample preparation/solid-phase derivatization of glycoprotein-derived N-linked glycans with their subsequent microchip-based separation and mass-sp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
162
1
1

Year Published

2010
2010
2020
2020

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 149 publications
(171 citation statements)
references
References 62 publications
7
162
1
1
Order By: Relevance
“…Solid phase permethylation was performed using the spin column technique developed in our laboratory (18,19). The samples were first dissolved in 70 l of dimethylformamide, 5 l of water, and 25 l of iodomethane.…”
Section: Methodsmentioning
confidence: 99%
“…Solid phase permethylation was performed using the spin column technique developed in our laboratory (18,19). The samples were first dissolved in 70 l of dimethylformamide, 5 l of water, and 25 l of iodomethane.…”
Section: Methodsmentioning
confidence: 99%
“…MS analýza může nebo nemusí používat derivatizaci vzorků, i když bylo mnohokrát prokázáno, že permetylace na pevné fázi [29] přináší jasné výhody co do zvýšené citlivosti a zahrnutí neutrálních i kyselých glykanových struktur v jednom analytickém měření. Různé detekční strategie pro LC a CE využívají mikrochemické navázání fl uoroforu ke glykanům, které jinak neobsahují jednoduše detekovatelné motivy ve svých molekulách.…”
Section: Glykomické Profi Lování Bio Logických Tekutin a Tkáníunclassified
“…46 A combination of GCB and C18 SPE columns has been used for the purification of glycans for methylation analysis. 47 Borate can be used to form a diester complex with vicinal diols of saccharides at a pH value greater than 8. Therefore, an anion exchange resin of borate form is the most straightforward method to trap saccharides.…”
Section: Specific Entrapment Of Glycansmentioning
confidence: 99%