2016
DOI: 10.1016/j.aca.2016.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Chitosan-iron oxide nanocomposite based electrochemical aptasensor for determination of malathion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
20
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 92 publications
(21 citation statements)
references
References 43 publications
1
20
0
Order By: Relevance
“…From these results it was possible to observe that the developed platform presented a good performance for the electrochemical detection of the pesticide in terms of reproducibility, once the relative standard deviation (RSD) for a given electrode was 1.4%, which value increased to 2.0% when three identical electrodes were used. The developed electrochemical sensor presented similar or even better performance for detecting malathion compared to other results reported in the literature, as displayed in table 1 [7,[35][36][37].…”
Section: Electrochemical Detection Of Malathionsupporting
confidence: 64%
See 2 more Smart Citations
“…From these results it was possible to observe that the developed platform presented a good performance for the electrochemical detection of the pesticide in terms of reproducibility, once the relative standard deviation (RSD) for a given electrode was 1.4%, which value increased to 2.0% when three identical electrodes were used. The developed electrochemical sensor presented similar or even better performance for detecting malathion compared to other results reported in the literature, as displayed in table 1 [7,[35][36][37].…”
Section: Electrochemical Detection Of Malathionsupporting
confidence: 64%
“…Among the pollutants, pesticides used in agriculture are considered hazardous chemicals if not properly used or managed [4][5][6]. Specifically, organophosphorus pesticides (OPs) are a group of organic pesticides that present high toxicity, and contribute with about 38% of the total pesticide used worldwide [7,8]. Such pesticides released in the natural environment can generate severe pollution problems, once they are not chemically specific and as a consequence, can affect several non-target species [9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…SWV has also been used for detection of a wide range of OPs over nanocompositemodified GCE. Nanocomposites employed for electrochemical detection of OPs were parathion [24][25][26][27][28], malathion [29,30] and paraoxon [31,32]. The nanocomposites employed for modification of GCE for OPs detection were zeolite [24], ZrO 2 [25], Au/Graphene [26,27], ZrO 2 [28], SWNT/GO [29], MWCNT [30], Au/Pt [31] and ZrO 2 /MWCNT [32].…”
Section: Introductionmentioning
confidence: 99%
“…Nanocomposites employed for electrochemical detection of OPs were parathion [24][25][26][27][28], malathion [29,30] and paraoxon [31,32]. The nanocomposites employed for modification of GCE for OPs detection were zeolite [24], ZrO 2 [25], Au/Graphene [26,27], ZrO 2 [28], SWNT/GO [29], MWCNT [30], Au/Pt [31] and ZrO 2 /MWCNT [32]. The nanomaterials used for detection of CHL were graphene [17], MWCNT [33][34][35], with nano-TiO 2 [36], carbon nitride [37], ferrocene [38], CuO [39].…”
Section: Introductionmentioning
confidence: 99%