Chronic softening spinal cord stimulation arrays

Abstract: Softening SCS arrays meet the needs for research-grade devices in rats and could be developed into human devices in the future.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
29
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 40 publications
(30 citation statements)
references
References 41 publications
1
29
0
Order By: Relevance
“…In conclusion, thiol-ene and thiol-ene/acrylate shape memory polymers are currently under development for a wide range of neural implant applications, including intracortical microelectrodes, spinal cord stimulators, sciatic-tibial-sural ‘Y’ electrodes, longitudinal intrafascicular electrodes, and self-coiling nerve cuff electrodes [ 22 , 35 , 40 , 78 , 79 , 80 ]. Here, our initial study sought to investigate the foreign body response to the material in absence of its mechanical softening properties so that as many extra and potentially confounding variables as possible could be eliminated.…”
Section: Discussionmentioning
confidence: 99%
“…In conclusion, thiol-ene and thiol-ene/acrylate shape memory polymers are currently under development for a wide range of neural implant applications, including intracortical microelectrodes, spinal cord stimulators, sciatic-tibial-sural ‘Y’ electrodes, longitudinal intrafascicular electrodes, and self-coiling nerve cuff electrodes [ 22 , 35 , 40 , 78 , 79 , 80 ]. Here, our initial study sought to investigate the foreign body response to the material in absence of its mechanical softening properties so that as many extra and potentially confounding variables as possible could be eliminated.…”
Section: Discussionmentioning
confidence: 99%
“…The ultimate goal is to utilize the hydrolytically stable SMP-A as a substrate for neural interfaces and therefore have an alternative to the currently used softeing SMP versions (Simon et al, 2017;Garcia-Sandoval et al, 2018). To validate that the polymer is compatible with microfabrication processes, SMP-A was spin-coated on silicon wafers and subjected to photolithography as previously decribed (Ecker et al, 2017).…”
Section: Discussionmentioning
confidence: 99%
“…Subsequently, oxygen plasma was applied to remove excess polymer and patterned photoresist. Finally, the sample was etched with hydrofluoric acid to remove SiN that was on the SMP (Garcia-Sandoval et al, 2018). The micro-fabricated pacifier probes were also used for the in vitro cytotoxicity test.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A wide range of biological phenomena can be observed with one or a matrix of extracellular electrodes . In addition, the same electrode may be used to deliver electrical stimulation to a local area of the tissue . To achieve higher resolution activity mapping, the number and density of electrodes are increased so that simultaneous recordings from a population of cells are collected with high temporal responses .…”
Section: Function and Compliance Of Bioelectronic Systemsmentioning
confidence: 99%