2010
DOI: 10.1016/j.jelechem.2010.05.018
|View full text |Cite
|
Sign up to set email alerts
|

Chronoamperometry on ring, ring-recessed and disk electrodes, and their arrays. The sensitive measurement of diffusion coefficients independent of a knowledge of concentration or number of electrons transferred

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 42 publications
0
4
0
Order By: Relevance
“…A direct determination of concentration has been proposed by electrical charge measurement but demanding a rigorous sample preparation [19,20]. Original methods for simultaneous determination are the use of two methods [21][22][23], measurements on electrodes with different forms [24,25]-planar or cylindrical [26], the use of one electrode on different timescales [27][28][29][30][31][32].…”
Section: Diffusion As Mass Transport For Direct Determination Of D 0 mentioning
confidence: 99%
See 1 more Smart Citation
“…A direct determination of concentration has been proposed by electrical charge measurement but demanding a rigorous sample preparation [19,20]. Original methods for simultaneous determination are the use of two methods [21][22][23], measurements on electrodes with different forms [24,25]-planar or cylindrical [26], the use of one electrode on different timescales [27][28][29][30][31][32].…”
Section: Diffusion As Mass Transport For Direct Determination Of D 0 mentioning
confidence: 99%
“…Other different possibilities of sizes and geometries of electrodes can be combined for a calibrationless method: a ring UME associated with planar, cylindrical or spherical electrode or a planar electrode associated with a spherical or cylindrical electrode. More recently numerical improvements in modeling allow to foresee more complex miniaturized systems [31,32], which could be of particular interest for in situ measurements.…”
Section: Chronoamperometry At Planar Electrodementioning
confidence: 99%
“…Table 3 shows real values of the rate constant that can be extracted with the proposed generator-collector devices. It should be noted though that presented values are calculated for a single generator-collector device, application of arrays of generator-collector devices should not change significantly range of the rate constants available for the measurement [22], although later is advantageous due to the higher currents generated. For the second order chemical reaction rate constant values as high as diffusion controlled can be measured.…”
Section: Discussionmentioning
confidence: 99%
“…Based on the above various fabrication methods, different types of micro electrode arrays (e.g., microdisk or microband electrode array and interdigitated, linear or 3D micro electrode array, etc.) have been reported (Fiaccabrino et al, 1996;Aguiar et al, 2007;Ordeig et al, 2008;Xu et al, 2008;Menshykau et al, 2010;Yi et al, 2016).…”
Section: Fabrication and Characteristics Of Micro/nano Electrode Arraysmentioning
confidence: 99%