2020
DOI: 10.4209/aaqr.2019.04.0179
|View full text |Cite
|
Sign up to set email alerts
|

Citizens' Surveillance Micro-network for the Mapping of PM2.5 in the City of Concón, Chile

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 0 publications
0
8
0
1
Order By: Relevance
“…How the sensor is incorporated into the LCM and the overall design of the LCM does make a difference on the performance. Low cost sensors can range from $10 to $ 700 and are used as an alternative for air quality monitoring assessment (Snyder et al, 2013;Kumar, 2015;Morawska et al, 2018;Bulot et al, 2019;Feenstra et al, 2019;Mao et al, 2019), including a viewpoint of citizen science (Clements et al, 2019;Golumbic et al, 2019;Wesseling et al, 2019;Gramsch et al, 2020;Park et al, 2020). These low-cost networks can use a larger number of LCMs for the same area (Kumar and Jasuja, 2017;Barot et al, 2020), providing high spatial and temporal resolution.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…How the sensor is incorporated into the LCM and the overall design of the LCM does make a difference on the performance. Low cost sensors can range from $10 to $ 700 and are used as an alternative for air quality monitoring assessment (Snyder et al, 2013;Kumar, 2015;Morawska et al, 2018;Bulot et al, 2019;Feenstra et al, 2019;Mao et al, 2019), including a viewpoint of citizen science (Clements et al, 2019;Golumbic et al, 2019;Wesseling et al, 2019;Gramsch et al, 2020;Park et al, 2020). These low-cost networks can use a larger number of LCMs for the same area (Kumar and Jasuja, 2017;Barot et al, 2020), providing high spatial and temporal resolution.…”
Section: Introductionmentioning
confidence: 99%
“…It is also well known that LCMs have calibration, accuracy and long term variation problems which require various calibration techniques (Miskell et al, 2018;Badura et al, 2019;van Zoest et al, 2019;Chu et al, 2020;Gramsch et al, 2020;Han et al, 2021). Some LCMs have nonlinear response to particle size, with most of them having low performance for large particles (Feenstra et al, 2019;Kuula et al, 2020).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The instrument allows the measurement of TSP and mass concentrations up to 6000 µg m −3 , PM 10 , PM 2.5 and PM 1 ; the relevant online data is summarized and presented in Table 2. Due to the fact that the TOPAS instrument went to maintenance and it was put offline on November 17 at 17:50 (UTC-5), the TOPAS was replaced with a new particle counter, Dylos DC1100 with PC interface (Gramsch et al 2020). The performance of the low-cost aerosol sensor (Dylos DC1100) compared to the TOPAS instrument was adequately validated prior to the data collection.…”
Section: Study Area and Instrumentationmentioning
confidence: 99%
“…El material particulado se encuentra en el polvo, cenizas, hollín, partículas metálicas, cemento o polen. Otras fuentes de origen son la combustión industrial y doméstica del carbón, de los procesos industriales, incendios, erosión eólica y erupciones volcánicas, de las construcciones, demoliciones y otros (Salini, Medina, 2017;Gramsch et al, 2020;Đorđević et al, 2020). Los efectos principales en la salud humana van desde la irritación en las vías respiratorias, deposición en los pulmones que origina enfermedades como la silicosis y la asbestosis, así como empeoran el asma y las enfermedades cardiovasculares (Gramsch et al, 2016).…”
Section: Introduccionunclassified