1988
DOI: 10.1111/j.1540-8191.1988.tb00239.x
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Experience with Expanded Polytetrafluoroethylene Gore-Tex® Surgical Membrane for Pericardial Closure: A Study of 110 Cases

Abstract: Complete closure of the pericardium after cardiac operations has the advantage of avoiding injury of the heart and great vessels during reoperation. Between 1985 and 1987, the pericardium was closed with Gore-Tex Surgical Membrane (SM) in a selected series of 110 patients 1 month to 76 years of age. Fifty-three patients had congenital heart lesions and 57 patients had acquired heart disease. Overall hospital mortality was 3/110 cases. In no instance was there a relationship between occurrence of death and peri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
22
0
3

Year Published

1995
1995
2016
2016

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(26 citation statements)
references
References 15 publications
1
22
0
3
Order By: Relevance
“…Eyes in the TG and TGMMC groups showed no adverse reaction to the material; neither inflammation nor extrusion nor conjuctival erosion were noted. Progressive discolouration with disappearance of the membrane, as already reported in cardiosurgical practice, was present in all cases (Minale et al 1988).…”
Section: Discussionsupporting
confidence: 71%
See 1 more Smart Citation
“…Eyes in the TG and TGMMC groups showed no adverse reaction to the material; neither inflammation nor extrusion nor conjuctival erosion were noted. Progressive discolouration with disappearance of the membrane, as already reported in cardiosurgical practice, was present in all cases (Minale et al 1988).…”
Section: Discussionsupporting
confidence: 71%
“…PRECLUDE Ò pericardial membrane is a white, opaque material, but after implantation the material becomes wet with proteinaceous, aqueous fluids and turns translucent. This is because of its microporous nature and the thinness of the material; this usually occurs within 2-6 weeks (Minale et al 1988;Leprince et al 2001).…”
Section: E-ptfe (Gore-texmentioning
confidence: 99%
“…Autologous 24 and heterologous pericardium, 25 anti-inflammatory 5 and fibrinolytic drugs, 26 synthetic 27,28 and biopolymers 8 are examples of therapies employed in these researches. But even with a large number of studies, none of them developed an alternative to improve the problems related to the way in which adhesions are measured.…”
Section: Discussionmentioning
confidence: 99%
“…Dieses nicht resorbierbare Material zeichnet sich durch seine Mikroporosität, Wasserdichtigkeit bei niedrigem Druck, Gas-und Wasserdampfdurchlässigkeit und minimale Gewebeadhäsionen bei den rekonstruktiven Verfahren aus. Die Nützlichkeit von e-PTFE als Ersatzstoff und seine minimierte Gewebeadhäsion wurden durch experimentelle Untersuchungen und klinische Studien belegt [12,35]. Die hydrophobe Eigenschaft von e-PTFE ermöglicht, dass das Wundgebiet postoperativ nicht an dem umliegenden Gewebe haftet.…”
unclassified