Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(31 citation statements)
references
References 28 publications
1
30
0
Order By: Relevance
“…They have shown huge success in breast radiotherapy, allowing for reduced margins, partial breast treatments and dose escalation [9,10]. In prostate radiotherapy, they are used routinely for image guidance in many institutions leading to increased setup accuracy, reduced target margins and dose escalation [11][12][13].…”
mentioning
confidence: 99%
“…They have shown huge success in breast radiotherapy, allowing for reduced margins, partial breast treatments and dose escalation [9,10]. In prostate radiotherapy, they are used routinely for image guidance in many institutions leading to increased setup accuracy, reduced target margins and dose escalation [11][12][13].…”
mentioning
confidence: 99%
“…Using the Pearson chi-square test with 5 degree of freedom, the χ 2 was 0.053 (p=0.95) for the LKB model and χ 2 was 0.058 (p=0. 95) for the Niemierko model suggesting a good fit for both models. Alexander et al 79 reported that the volume parameter exhibited a strong effect on breast fibrosis.…”
Section: Resultsmentioning
confidence: 80%
“…Each patient underwent two planning CT scans on separate It is now known that surgical clips are a better surrogate of the surgical cavity (tumour bed), as compared to bony anatomy. A number of studies have evaluated the feasibility of using these surgical clips for image guided breast radiotherapy [94][95][96] .…”
Section: Central Lung Distance (Cld)mentioning
confidence: 99%
“…Gold fiducial markers were implanted near the seroma cavity as a surrogate for its position on orthogonal MV portal imaging. 17 However, the issue of MV exit dose to structures such as the contralateral breast remains because of the use of orthogonal beam projections. The study did not determine whether fiducial markers implanted under ultrasound guidance maintained their relationship with the seroma cavity in the manner Weed et al demonstrated for clips implanted at the time of surgery.…”
Section: Discussionmentioning
confidence: 99%