Abstract: The purpose of this study was to compare two clinical immobilization systems for intracranial frameless stereotactic radiosurgery (fSRS) under the same clinical procedure using cone-beam computed tomography (CBCT) for setup and videobased optical surface imaging (OSI) for initial head alignment and intrafractional motion monitoring. A previously established fSRS procedure was applied using two intracranial immobilization systems: PinPoint system (head mold and mouthpiece) and Freedom system (head mold and open… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
45
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 35 publications
(45 citation statements)
references
References 15 publications
0
45
0
Order By: Relevance
“…[1][2][3][4] Our institution has previously published on the use of FFF-VMAT stereotactic radiotherapy (SRT) to significantly reduce treatment time 5 as well as utilizing a single isocenter for the treatment of multiple brain metastases. [1][2][3][4] Our institution has previously published on the use of FFF-VMAT stereotactic radiotherapy (SRT) to significantly reduce treatment time 5 as well as utilizing a single isocenter for the treatment of multiple brain metastases.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…[1][2][3][4] Our institution has previously published on the use of FFF-VMAT stereotactic radiotherapy (SRT) to significantly reduce treatment time 5 as well as utilizing a single isocenter for the treatment of multiple brain metastases. [1][2][3][4] Our institution has previously published on the use of FFF-VMAT stereotactic radiotherapy (SRT) to significantly reduce treatment time 5 as well as utilizing a single isocenter for the treatment of multiple brain metastases.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4] Our institution has previously published on the use of FFF-VMAT stereotactic radiotherapy (SRT) to significantly reduce treatment time 5 as well as utilizing a single isocenter for the treatment of multiple brain metastases. 4,7,8 We recently commissioned an Edge (Varian Medical Systems, Palo Alto, CA) linear accelerator with an optical surface monitoring system (OSMS), a camera based system for surface guided radiation therapy (SGRT), to monitor all SRT patients for intrafraction motion. 4,7,8 We recently commissioned an Edge (Varian Medical Systems, Palo Alto, CA) linear accelerator with an optical surface monitoring system (OSMS), a camera based system for surface guided radiation therapy (SGRT), to monitor all SRT patients for intrafraction motion.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, marker-less range (distance) imaging systems, such as stereovision systems [e.g., AlignRT system (VisionRT, Ltd., London, UK)] [9][10][11] and laser range scanners [e.g., Galaxy system (LAP Laser, Lünberg, Germany)] [12], have been introduced for monitoring intra-fractional patient motion. Range images can be defined as three-dimensional (3D) images, i.e., point distribution representation of the patient surface with 3D coordinates in the Cartesian coordinate system.…”
Section: Introductionmentioning
confidence: 99%