2003
DOI: 10.2209/tdcpublication.44.159
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Validity of the Interactive and Low-Dose Three-Dimensional Dento-Alveolar Imaging System, Tuned-Aperture Computed Tomography

Abstract: Based on technical studies and clinical examinations, the clinical value of a new three-dimensional dento-alveolar imaging system, Tuned-Aperture Computed Tomography (TACT ® ), were examined for dental applications. TACT is a conventional and low-cost tomosynthesis method in which the benefit of digitization is fully utilized. The clinical information yield of TACT has been examined for the detection of dental caries, periodontal defects and radicular fractures, and also for the pre-surgical assessment of impl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 46 publications
0
4
0
1
Order By: Relevance
“…Several studies have applied digital tomosynthesis to dentistry [25][26][27][28][29][30][31][32], but it has not been widely applied to clinical use due to the limits of the technology at this time. Our team proposed the 2.5D Periapical Radiography System in 2018 [8] and developed a high-frame-rate sensor.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have applied digital tomosynthesis to dentistry [25][26][27][28][29][30][31][32], but it has not been widely applied to clinical use due to the limits of the technology at this time. Our team proposed the 2.5D Periapical Radiography System in 2018 [8] and developed a high-frame-rate sensor.…”
Section: Discussionmentioning
confidence: 99%
“…Our research on TACT imaging [3][4][5] is the second in vivo study. The first such study was reported by the inventor, R.L.…”
Section: Discussionmentioning
confidence: 99%
“…His group concluded that TACT displays were more diagnostically informative and had more impact on potential treatment options than did conventional radiographs. Some in vitro studies indicated that TACT is sensitive or compatible in comparison with conventional dento-alveolar radiography examinations to detect dental caries, periodontal bone dynamics and other diagnostic tasks [4,5].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Bu sorun, cihazın kullanımını komplike hale getirdiği gibi, elde edilecek 3 boyutlu görüntünün kalitesini de bozmaktadır. 22 Hata! Başvuru kaynağı bulunamadı.…”
unclassified