2021
DOI: 10.1016/j.egyr.2021.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Coefficient of performance and heating and cooling thermal performance characteristics using a standing column well and cross-mixing balancing well heat exchanger methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…In the literature both experimental (Beaudry et al, 2019;Cho et al, 2016;Lee et al, 2019;Lim and Lee, 2021;Minea, 2013;Nguyen et al, 2020;Orio et al, 2005;Pasquier et al, 2016) and simulation studies (Beaudry et al, 2022(Beaudry et al, , 2021Nguyen et al, 2013) addressed the performance of GSHP systems using SCWs, some of which also explored different groundwater bleeding strategies (Beaudry et al, 2022;Nguyen et al, 2020Nguyen et al, , 2013.…”
Section: Standing Column Wells In Cold Climatesmentioning
confidence: 99%
“…In the literature both experimental (Beaudry et al, 2019;Cho et al, 2016;Lee et al, 2019;Lim and Lee, 2021;Minea, 2013;Nguyen et al, 2020;Orio et al, 2005;Pasquier et al, 2016) and simulation studies (Beaudry et al, 2022(Beaudry et al, , 2021Nguyen et al, 2013) addressed the performance of GSHP systems using SCWs, some of which also explored different groundwater bleeding strategies (Beaudry et al, 2022;Nguyen et al, 2020Nguyen et al, , 2013.…”
Section: Standing Column Wells In Cold Climatesmentioning
confidence: 99%
“…In the literature both experimental Cho et al, 2016;Lee et al, 2019;Lim and Lee, 2021;Minea, 2013;Orio et al, 2005; and simulation studies Nguyen et al, 2013) addressed the performance of GSHP systems using SCWs, some of which also explored different groundwater bleeding strategies Nguyen et al, , 2013.…”
Section: Standing Column Wells In Cold Climatesmentioning
confidence: 99%
“…The modified unit was tested under various ranges of ambient temperatures to compare with the traditional outdoor unit. The results showed that the modified unit reduced 2.2 o C temperature when the outdoor temperature was 35 o C. In addition, it enhanced the refrigerating capacity, power consumption, and energy efficiency ratio by 8.1%, -9.5%, and 20%, respectively at the ambient temperature of 43 o C. Lim & Lee [20] conducted an experimental investigation to improve the thermal performance characteristics of a proposed geothermal system using a standing column well (SCW) and cross-mixing balancing well heat exchanger methods. The analysis was done by preventing underground water discharge and maintaining a constant temperature of the underground heat exchanger.…”
Section: Introductionmentioning
confidence: 96%