2016
DOI: 10.1016/j.seizure.2015.11.001
|View full text |Cite
|
Sign up to set email alerts
|

Color density spectral array of bilateral bispectral index system: Electroencephalographic correlate in comatose patients with nonconvulsive status epilepticus

Abstract: b-BIS monitoring system and, in particular, CDSA used by nonexpert NICU personnel may be helpful to follow-up episodes of NCSE, to detect recurrences of nonconvulsive seizures (NCSzs), and to monitor profound anesthetic therapy in comatose patients when cEEG is not available.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(17 citation statements)
references
References 39 publications
2
15
0
Order By: Relevance
“…[100][101][102] The spike-and-wave discharges during NCSE (Fig. 3A) 103 vary in character depending on the aetiology. 102 These EEG complexes can be difficult to distinguish from triphasic waves (Fig.…”
Section: Triphasic Wavesmentioning
confidence: 99%
“…[100][101][102] The spike-and-wave discharges during NCSE (Fig. 3A) 103 vary in character depending on the aetiology. 102 These EEG complexes can be difficult to distinguish from triphasic waves (Fig.…”
Section: Triphasic Wavesmentioning
confidence: 99%
“…In one study, using a 1-channel montage, authors found a sensitivity of 40% for the identification of seizure by nonexperts ICUs physicians [ 12 ]. Another type of quantitative EEG frequently used is compressed spectral array, which can identify seizure patterns with a very good accuracy [ 13 , 14 ]. However qEEG do not allow instantaneous diagnosis of seizure.…”
Section: Discussionmentioning
confidence: 99%
“…In ICU, BIS monitors are used in different contexts when patients have intracranial hypertension BIS and SR values are used to titrate barbiturate treatment [ 10 , 11 ]; when patients have refractory status epilepticus, BIS and SR values are used to guide the depth of sedation if cEEG is not available because there is a strong correlation between BIS and SR values and the burst rate monitored with conventional EEG [ 12 , 13 ].…”
Section: Discussionmentioning
confidence: 99%
“…CDSA uses Fourier transformation to process long-term EEG signals and converts EEG parameters (such as power, amplitude, and frequency) into visualized images, making it possible to evaluate the dynamic EEG changes in different-frequency bands. [9] Recently, CDSA has been widely used in the clinical evaluation of patients with sleep disorders and epilepsy. However, the application value of CDSA in brain function monitoring has not yet been well elucidated.…”
Section: Discussionmentioning
confidence: 99%