2015
DOI: 10.1016/j.snb.2015.04.091
|View full text |Cite
|
Sign up to set email alerts
|

Colorimetric detection of cholesterol based on highly efficient peroxidase mimetic activity of graphene quantum dots

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
68
1
6

Year Published

2016
2016
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 170 publications
(75 citation statements)
references
References 48 publications
0
68
1
6
Order By: Relevance
“…[35] Theprotocol is reliable enough and has been used for analysis of glucose in actual samples, such as diluted blood and commercial fruit juices. [35] More importantly,t his can be au niversal assay when acetylcholinesterase (AChE), [78] choline oxidase (ChOx), [78] cholesterol oxidase (COx), [56,58,101,171] or d-amino acid oxidase-(DAAO) [133] is used instead of GOx, which can catalyze O 2 to oxidize the corresponding substrate such as the acetylcholine, [78] choline [78] and cholesterol, [56,58,101,171] and d-amino acids to produce H 2 O 2 .…”
Section: Biosensors For Biomolecules That Canproduce H 2 Omentioning
confidence: 99%
“…[35] Theprotocol is reliable enough and has been used for analysis of glucose in actual samples, such as diluted blood and commercial fruit juices. [35] More importantly,t his can be au niversal assay when acetylcholinesterase (AChE), [78] choline oxidase (ChOx), [78] cholesterol oxidase (COx), [56,58,101,171] or d-amino acid oxidase-(DAAO) [133] is used instead of GOx, which can catalyze O 2 to oxidize the corresponding substrate such as the acetylcholine, [78] choline [78] and cholesterol, [56,58,101,171] and d-amino acids to produce H 2 O 2 .…”
Section: Biosensors For Biomolecules That Canproduce H 2 Omentioning
confidence: 99%
“…Briefly, a K 3 [Fe(CN) 6 ] aqueous solution (90 mL, 0.05 M) was added dropwise (1 mL/min) to a mixture of excess solutions of Co 2 + (150 mL, 0.05 M) and Mn 2 + (150 mL, 0.05 M) sulfates. Briefly, a K 3 [Fe(CN) 6 ] aqueous solution (90 mL, 0.05 M) was added dropwise (1 mL/min) to a mixture of excess solutions of Co 2 + (150 mL, 0.05 M) and Mn 2 + (150 mL, 0.05 M) sulfates.…”
Section: Synthesis and Characterizationmentioning
confidence: 99%
“…A simple, easy-to-use cholesterol sensor device is an attractive alternative to avoid this potential diagnostic delay. Other techniques which have been reported to detect lipid 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 levels are colorimetry [7], chromatography [8], spectrophotometry [9], electrochemiluminescence [10] and electrochemistry [11]. Due to its simplicity, economic feasability, rapid analysis and portability, electrochemistry is an interesting and widely studied technique.…”
Section: Introductionmentioning
confidence: 99%