Combination of Real Time Three‐Dimensional Echocardiography with Diagnostic Catheterization to Derive Left Ventricular Pressure‐Volume Relations

Abstract: Emax can be determined from RT3DE integrated with catheterization-derived pressures. RT3DE is a promising method for enhancing clinical applicability of pressure-volume relations for assessment of myocardial contractility.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 26 publications
0
3
1
Order By: Relevance
“…For technical reasons, PVL 3D and PVL Cond could not be obtained simultaneously. In contrast to findings in adult pigs [ 22 ], we observed intracavital echocardiographic artifacts in the small ventricles of piglets produced by the conductance catheter which impaired the semiautomatic contour analysis of left ventricular borders during 3DE volume calculation. Therefore the conductance catheter had to be removed during 3DE image acquisition.…”
Section: Discussioncontrasting
confidence: 99%
See 2 more Smart Citations
“…For technical reasons, PVL 3D and PVL Cond could not be obtained simultaneously. In contrast to findings in adult pigs [ 22 ], we observed intracavital echocardiographic artifacts in the small ventricles of piglets produced by the conductance catheter which impaired the semiautomatic contour analysis of left ventricular borders during 3DE volume calculation. Therefore the conductance catheter had to be removed during 3DE image acquisition.…”
Section: Discussioncontrasting
confidence: 99%
“…The echocardiographic evaluation of beat-to-beat variability is only possible using the technique of single-beat acquisition of 3D datasets with low temporal and spatial resolution [ 31 ]. Kutty et al [ 22 ] integrated 3D single-beat volume data derived by transesophageal 3DE (TEE) with left ventricular pressure curves from a conductance catheter in adult pig hearts. Despite using TEE, their temporal resolution was poor compared to our study (12–14 3D volumes/s vs. 36.5 ± 2.7 3D volumes/s).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Signals were displayed by the CFL-M Inca (CD Leycom, Hengelo, The Netherlands). Volume calibration was done in baseline measurements using end diastolic volume (EDV) and end systolic volume (ESV) obtained by 3DE as references [7,13].…”
Section: Plos Onementioning
confidence: 99%