2016
DOI: 10.1007/s12350-016-0570-8
|View full text |Cite
|
Sign up to set email alerts
|

Combined assessment of myocardial perfusion and left ventricular function by nuclear cardiology: The value of high-efficiency SPECT

Abstract: The introduction of ECG gating to myocardial perfusion SPECT imaging (MPI) more than 20 years ago provided the opportunity for the combined assessment of myocardial perfusion and left ventricular (LV) function with a single radiotracer injection.1 Software for automatic quantification of left ventricular volume and ejection fraction (EF) was developed, and ECGgated SPECT became a widespread, routine part of MPI acquisition and interpretation.2 Although simultaneously acquired, myocardial perfusion images repre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…7 The recent introduction of the cadmium-zinc-telluride (CZT) cameras for SPECT has purportedly revolutionized MPI, thanks to their superior spatial and energy resolution. 8,9 Given their groundbreaking technical features and the differences between the two available but competing suites (D-SPECT, Spectrum Dynamics, Palo Alto, CA, USA; Discovery NM 530c or Discovery NM/CT 570c with Alcyone technology, GE Healthcare, Haifa, Israel), there are, however, ongoing developments and refinements in the application of this imaging technology to current cardiovascular practice. [10][11][12] Accordingly, the scholarly literature on CZT MPI is continuing to expand momentously, as demonstrated by the work by Jameria and colleagues published in this issue of the Journal.…”
Section: See Related Article Pp 540-549mentioning
confidence: 99%
See 1 more Smart Citation
“…7 The recent introduction of the cadmium-zinc-telluride (CZT) cameras for SPECT has purportedly revolutionized MPI, thanks to their superior spatial and energy resolution. 8,9 Given their groundbreaking technical features and the differences between the two available but competing suites (D-SPECT, Spectrum Dynamics, Palo Alto, CA, USA; Discovery NM 530c or Discovery NM/CT 570c with Alcyone technology, GE Healthcare, Haifa, Israel), there are, however, ongoing developments and refinements in the application of this imaging technology to current cardiovascular practice. [10][11][12] Accordingly, the scholarly literature on CZT MPI is continuing to expand momentously, as demonstrated by the work by Jameria and colleagues published in this issue of the Journal.…”
Section: See Related Article Pp 540-549mentioning
confidence: 99%
“…In light of the work of Jameria and colleagues, and the total body of evidence on this topic, [8][9][10][11][12] it is important to highlight the current and future prospects of CZT technology for MPI. First, it is paramount to recognize that the two available embodiments of this technology (Alcyone and D-SPECT) might not be identical in performance, despite aggregate analyses suggesting the contrary.…”
Section: See Related Article Pp 540-549mentioning
confidence: 99%