2024
DOI: 10.3390/jcm13082434
|View full text |Cite
|
Sign up to set email alerts
|

Comment on Grabala et al. Radiological Outcomes of Magnetically Controlled Growing Rods for the Treatment of Children with Various Etiologies of Early-Onset Scoliosis—A Multicenter Study. J. Clin. Med. 2024, 13, 1529

Casper S. Tabeling,
Justin V. C. Lemans,
Moyo C. Kruyt

Abstract: We read with great interest the study titled “Radiological Outcomes of Magnetically Controlled Growing Rods for the Treatment of Children with Various Etiologies of Early-Onset Scoliosis—A Multicenter Study” by Grabala and colleagues [...]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…Furthermore, congruent T1-T12 and T1-S1 extension values were noted during MCGR insertion surgery, with T1-T12 and T1-S1 parameters escalating by 52% and 51% of the total length achieved since MCGR implantation through the elongation process, resulting in an increase in T1-T12 and T1-S1 by 48% and 49%, respectively [15]. In reference to the analysis by the authors of the commentary concerning the T1-T12 and T1-S1 values [2], and the Cobb angle of the primary curvature, it can be deduced from our findings that despite the adverse parameters and potential complications arising from MCGR treatment, the application of magnetic rods allows for the attainment of satisfactory radiological and clinical outcomes.…”
mentioning
confidence: 91%
See 4 more Smart Citations
“…Furthermore, congruent T1-T12 and T1-S1 extension values were noted during MCGR insertion surgery, with T1-T12 and T1-S1 parameters escalating by 52% and 51% of the total length achieved since MCGR implantation through the elongation process, resulting in an increase in T1-T12 and T1-S1 by 48% and 49%, respectively [15]. In reference to the analysis by the authors of the commentary concerning the T1-T12 and T1-S1 values [2], and the Cobb angle of the primary curvature, it can be deduced from our findings that despite the adverse parameters and potential complications arising from MCGR treatment, the application of magnetic rods allows for the attainment of satisfactory radiological and clinical outcomes.…”
mentioning
confidence: 91%
“…We are immensely gratified by the considerable interest our study has garnered [ 1 ], leading to a multitude of correspondences and official remarks [ 2 ]. The scrutiny of our work and the comprehensive analysis of the research findings will result in a juxtaposition with other studies [ 3 , 4 , 5 , 6 , 7 , 8 , 9 ], thereby enriching the advancement of spinal surgery and enhancing the surgical methodologies employed in treating pediatric patients afflicted with early-onset spinal deformities.…”
mentioning
confidence: 99%
See 3 more Smart Citations