Common Questions on Partial Discharge Testing: A Review of Recent Developments in IEEE and IEC Standards for Offline and Online Testing of Motor and Generator Stator Windings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(11 citation statements)
references
References 1 publication
0
9
0
2
Order By: Relevance
“…However, to achieve the LVRT requirements, once the sag happened, the reactive current is injected based on the sag depth. In this context, the amount of maximum active current (I d ) injected to the grid is estimated according to Equation (7) in which the amount of active and reactive current not exceeding 110% of the inverter rated current (I n ) following to Equation (8).…”
Section: Lvrt Capability Control For Voltage Sag Mitigationmentioning
confidence: 99%
See 1 more Smart Citation
“…However, to achieve the LVRT requirements, once the sag happened, the reactive current is injected based on the sag depth. In this context, the amount of maximum active current (I d ) injected to the grid is estimated according to Equation (7) in which the amount of active and reactive current not exceeding 110% of the inverter rated current (I n ) following to Equation (8).…”
Section: Lvrt Capability Control For Voltage Sag Mitigationmentioning
confidence: 99%
“…Figure 1 illustrates the amount of PV system capacity and annual addition in the recent ten years [1]. PVPPs have various characteristics that differ from the traditional power plants, which in turn lead to new For power quality, grid codes from countries such as Germany [3], Italy [4], USA [5], Australia [6], and many international standards like IEC standards [7] and IEEE standards [8] have enforced strict power quality rules for PV and other renewable energy sources (RESs) integration. For instance, during voltage sag, which is normally caused by the grid faults, the new requirements necessitate injecting reactive current into the PV system to overcome the sag event and to support the grid stability [9,10].…”
Section: Introductionmentioning
confidence: 99%
“…Relevant PD tests for stator are briefly described and discussed by Stone et al [8] in a format of a simple FAQ for a broad audience. Standardized test methods can be found in IEEE std 1434-2014 [4] and IEC 60034-18-34 [9].…”
Section: Diagnostic Techniques Used Todaymentioning
confidence: 99%
“…It often occurs with secondary physical phenomena such as light and sound generation, temperature fluctuation, electromagnetic wave emission, and chemical reactions. (6)(7)(8)(9)(10) By measuring these relative performance characteristics of PD, potential internal threats can be detected so that GIS faults can be recognized and eliminated in advance.…”
Section: Introductionmentioning
confidence: 99%