Abstract: <H4>PURPOSE</H4> <p>To assess the comparability and intra-/ interobsever reliability of central anterior chamber depth measurements obtained using the Pentacam and IOLMaster.</p> <H4>METHODS</H4> <p>Anterior chamber depth was measured in 50 eyes (25 healthy volunteers)—three times on each eye by two independent observers with each method. A total of 12 measurements were performed on each eye. Analysis of variance was used to analyze the data. Mean values, standard d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
8
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(9 citation statements)
references
References 11 publications
0
8
1
Order By: Relevance
“…Our results are not in agreement with Savant et al (22) and Woodmass and Rocha (2), who did not obtain any statistically significant differences between Pentacam and IOLMaster, which may be due to their small sample size and inclusion of normal eyes only in the Savant et al (22) study.…”
Section: Discussioncontrasting
confidence: 99%
“…Our results are not in agreement with Savant et al (22) and Woodmass and Rocha (2), who did not obtain any statistically significant differences between Pentacam and IOLMaster, which may be due to their small sample size and inclusion of normal eyes only in the Savant et al (22) study.…”
Section: Discussioncontrasting
confidence: 99%
“…4,19 In addition, several studies have compared this Scheimpflug system with established clinical instruments for measuring corneal thickness [9][10][11]13,20,21 and anterior chamber parameters. 15,16,18,20,22,23 23 To evaluate the capability of the Pentacam HR system to measure anterior corneal topography, we compared its measurements in a large population of young adult subjects with normal corneas with measurements taken with a Placido disk-based videokeratoscope (Medmont E300, Medmont Pty. Ltd.) that has been found to be highly accurate and repeatable.…”
mentioning
confidence: 99%
“…The IOLMaster uses partial coherent interferometry in measuring axial length and optical pachymetry in measuring ACD 2–5,9–12 . Both of these techniques may be affected by accommodation and ACD appears to be reduced during accommodation 13 .…”
mentioning
confidence: 99%
“…The IOLMaster uses partial coherent interferometry in measuring axial length and optical pachymetry in measuring ACD. [2][3][4][5][9][10][11][12] Both of these techniques may be affected by accommodation and ACD appears to be reduced during accommodation. 13 In axial length measurement, the IOLMaster converts optical path length into geometrical length using an average refractive index.…”