2004
DOI: 10.1016/j.ab.2004.02.027
|View full text |Cite
|
Sign up to set email alerts
|

Comparative analyses of a small molecule/enzyme interaction by multiple users of Biacore technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 73 publications
(58 citation statements)
references
References 11 publications
0
58
0
Order By: Relevance
“…The fitting model also contained a floating term to correct for slight changes in the bulk refractive index of analyte solutions. SPR data were double-referenced [35], i.e. corrected for analyte solution responses as well as pure buffer responses, the former reflecting bulk refractive index changes and the latter any background instrumental "noise".…”
Section: Surface Plasmon Resonance Analysesmentioning
confidence: 99%
“…The fitting model also contained a floating term to correct for slight changes in the bulk refractive index of analyte solutions. SPR data were double-referenced [35], i.e. corrected for analyte solution responses as well as pure buffer responses, the former reflecting bulk refractive index changes and the latter any background instrumental "noise".…”
Section: Surface Plasmon Resonance Analysesmentioning
confidence: 99%
“…We also created a reference surface by performing the aminecoupling procedure in the absence of CA II on another flow cell surface. We dissolved acetazolamide (ACZ; Sigma) in Dulbecco's phosphate-buffered saline (Sigma), and sequentially injected this solution over each surface at 100 l/min for 1 min, followed by a 7-min dissociation interval, similar to previous investigators (26). The pure SLC4-Ct peptides, diluted in HBS-EP buffer (10 mM HEPES, pH 7.4, 150 mM NaCl, 3 mM EDTA, 0.005% surfactant P20; Biacore AB) containing 100 M tris(2-carboxyethyl)phosphine hydrochloride (Sigma), were injected over the CA II and reference surfaces at 25 l/min for 2.4 min followed by a 5-min dissociation interval.…”
Section: Solid-phase Binding Assays With Spr Detectionmentioning
confidence: 99%
“…We then subtracted the mean response of 2-3 buffer injections from each active-surface sensorgram to correct for drift in the data. To fit kinetic parameters to the ACZ binding data, we used a 1:1 Langmuir binding model that includes a correction for mass transfer effects (26).…”
Section: Data Analysis and Statisticsmentioning
confidence: 99%
“…Of the 678 articles that stated which Biacore platform was used, most utilized 2000 and 3000 platforms [222, (33%) and 249 (37%), respectively]. Investigators also reported data obtained from Biacore X (129, 19%) and 1000 (57, 8%), as well as from S51 [273,818,831,843,865], J [223,285,737,745,759], Q [892,905,907,910,913], Bialite [492,726,787,873] and Probe [348] platforms.…”
Section: Instrumentsmentioning
confidence: 94%