2015
DOI: 10.1002/jps.24454
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of Analytical Techniques for Determining Protein Charge

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
94
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(95 citation statements)
references
References 27 publications
1
94
0
Order By: Relevance
“…Likewise, NMR spectroscopy revealed that neither K þ nor Na þ significantly perturbed PC liposome spectra (42), and estimates of the binding constants for Na , and Na þ ions. However, in general, ELS charge measurements for macromolecules the size of Nanodiscs have poor precision (15), which is evident in the ELS mobility data for PC vesicles, where the uncertainty nearly equals or exceeds the reported mobility (25).…”
Section: Polyelectrolyte Behavior Of Lipid Nanodiscsmentioning
confidence: 99%
See 2 more Smart Citations
“…Likewise, NMR spectroscopy revealed that neither K þ nor Na þ significantly perturbed PC liposome spectra (42), and estimates of the binding constants for Na , and Na þ ions. However, in general, ELS charge measurements for macromolecules the size of Nanodiscs have poor precision (15), which is evident in the ELS mobility data for PC vesicles, where the uncertainty nearly equals or exceeds the reported mobility (25).…”
Section: Polyelectrolyte Behavior Of Lipid Nanodiscsmentioning
confidence: 99%
“…The uncertainty in Z DHH from MCE measurements is estimated to be 56% (9,40), or 50.8 charge units for POPC Nanodiscs. Although it is difficult to estimate the uncertainty in the charge calculated from the amino acid composition, it is almost certainly greater than 6% (15). Even if the calculated MSP1D1 charge was accurate, the resulting POPC charge would be near neutral (þ0.06/lipid, calculated as þ1.9 per 63 lipid molecules).…”
Section: Polyelectrolyte Behavior Of Lipid Nanodiscsmentioning
confidence: 99%
See 1 more Smart Citation
“…The electrophoretic mobility of BSA in 10 mM Tris + 10 mM NaCl at pH 8.1 was measured using ELS in two different instruments, capillary electrophoresis, and membrane confined electrophoresis [54]. Results obtained by the various methods were in general but not precise agreement, and values of the Debye-Hückel-Henry effective charge calculated from these mobilities were likewise in general but not precise agreement with results calculated from hydrogen ion titration and analysis of amino acid sequence and protein structure.…”
Section: Topics Of Concernmentioning
confidence: 99%
“…We are left in a quandary. However, based on the premise that z p is the charge contained in a hypothetical volume defined by the Stokes radius, Filoti et al proposed that z DHH is an accurate estimate of z P if the Debye-Hückel cloud is considered to be the solvent response to z P (Filoti et al 2015).…”
mentioning
confidence: 99%