2015
DOI: 10.1002/elan.201500578
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of Carbon Paste, Screen Printed, and PVC Potentiometric Sensors Based on Copper‐sulphamethazine Schiff Base Complex for Determination of Iodide – Experimental and Theoretical Approaches

Abstract: [a] 1IntroductionIodide is necessary for human health as it guarantees the proper thyroid gland function and it is used as antiseptic for skin wounds.I odidea lso exists in food, drug compound and in drinking water and it is added to table salts as as upply of iodine to prevent iodine shortage disorders [1].I na ddition, it is used as catalyst or stabilizer in polymer production and as purifying agent of drinking and swimming pool waters. Therefore,d etermination of iodide in the field of food, biological, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 39 publications
0
18
0
Order By: Relevance
“…To investigate the effect of MIP and NIP structure on sensor performance, sensor 6 was formulated in the same way and the composition of sensor 5 except NIP was used as a recognition element instead of MIP. Sensor 6 exhibited a lower response compared to sensor 5 due to the absence of the host–guest interaction as no cavities exist in NIP particles, and only H-bonding takes place on the surface of the NIP particles ( Abdel-Haleem and Shehab, 2016 ). According to these data, sensor 5 versus sensors 4 and 6 (as a control) were further investigated in subsequent studies, i.e., SEM-EDS, selectivity against interfering species, applicability of pH range, sensor reversibility, response, and lifetime, bonding strength, and formation constant estimation.…”
Section: Resultsmentioning
confidence: 99%
“…To investigate the effect of MIP and NIP structure on sensor performance, sensor 6 was formulated in the same way and the composition of sensor 5 except NIP was used as a recognition element instead of MIP. Sensor 6 exhibited a lower response compared to sensor 5 due to the absence of the host–guest interaction as no cavities exist in NIP particles, and only H-bonding takes place on the surface of the NIP particles ( Abdel-Haleem and Shehab, 2016 ). According to these data, sensor 5 versus sensors 4 and 6 (as a control) were further investigated in subsequent studies, i.e., SEM-EDS, selectivity against interfering species, applicability of pH range, sensor reversibility, response, and lifetime, bonding strength, and formation constant estimation.…”
Section: Resultsmentioning
confidence: 99%
“…ISE response mechanism can be predicted from the effect of lipophilic additive type, where membrane electrodes based on neutral carriers get improved slope and selectivity by adding sites with a charge opposite to that of the primary ion . In this study, the effect of addition of KTpClPB and TDMACl as anionic and cationic lipophilic additives on the electrodes response characteristics was investigated.…”
Section: Resultsmentioning
confidence: 99%
“…The commercial pharmaceutical preparation Levoxin ® (500 mg coated tablet of levofloxacin) was bought from the local market. HCl/KCl buffer of pH 2.2 and Acetate buffer of pH 4.1 were prepared and used for the preparation of (10 −2 M) LF which was used to prepare the more diluted solutions [ 34 , 35 ]. Reduced graphene oxide (RGO) was prepared by the reduction of GO using NaBH 4 [ 36 ].…”
Section: Methodsmentioning
confidence: 99%