2018
DOI: 10.19184/jrsl.v2i01.7435
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of the Behaviour of Building Structure of Hotel Dafam Lotus Jember by Using Moment Resisting Frame and Eccentrically Braced Frame

Abstract: Eccentrically Braced Frame (EBF) is one of several types of braces that can be used in steel building. EBF has a good stiffness and ductility to withstand earthquake load. In EBF itself there are 3 types of links, namely: Long Link, Intermediate Link, and Short Link. Meanwhile, MRF of Moment resisting Frame is a structural system where the beams and columns are connected rigidly. MRF has a good ductility in accepting load even it has no lateral braces installed. In this research the Dafam Lotus Jember hotel co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…(2024). Semesta Teknika,27(1) https://journal.umy.ac.id/index.php/st/issue/view/1064 a positive association between the length of the link and the magnitude of the shear force (Ahmadi, Ricles, and Sause, 2018;Kurniawan, Nurtanto and Hayu, 2018;Tanijaya, 2021).…”
Section: Equivalent Lateral Forcementioning
confidence: 99%
See 1 more Smart Citation
“…(2024). Semesta Teknika,27(1) https://journal.umy.ac.id/index.php/st/issue/view/1064 a positive association between the length of the link and the magnitude of the shear force (Ahmadi, Ricles, and Sause, 2018;Kurniawan, Nurtanto and Hayu, 2018;Tanijaya, 2021).…”
Section: Equivalent Lateral Forcementioning
confidence: 99%
“…Moreover, it is crucial to recognize that the application of bracing serves a pivotal function in mitigating the impact of bending moment and shear stresses exerted on columns (Ronagh, 2011;Alwaeli et al, 2017;Ccahuana, Coronel, & Soto, 2020). However, it is imperative to acknowledge that this particular approach to bracing leads to a concomitant increase in the axial compression experienced by the columns that are connected to the braced columns (Kurniawan, Nurtanto, & Hayu, 2018;Gusella et al, 2019;Yao et al, 2020). The incorporation of eccentric reinforcement inside the system results in a decrease in its lateral stiffness while simultaneously enhancing its energy dissipation capabilities.…”
Section: Introductionmentioning
confidence: 99%