Comparison among different diagnostic systems for medium voltage cable lines

Abstract: The progressive liberalization of the market of electric power gives the user new opportunities in terms of selection of electrical and integrated services providers and motivates electric companies to increase the quality of services offered limiting their costs. In the medium voltage distribution networks, one of the most effective technical drivers to reach a higher level of power quality is the optimization of the cable network operation; this can be achieved through the application of diagnostic tools abl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 3 publications
0
9
0
1
Order By: Relevance
“…A test on XLPE material showed that although differences are limited, PDIV seems to be lower when testing with a lower frequency rather than a higher one [88]. Field experiences (paper, EPR, and XLPE cable) [99] showed that neither 0. Energies 2021, 14, x FOR PEER REVIEW 8 of 21 circumstances.…”
Section: Off-line Testmentioning
confidence: 96%
See 1 more Smart Citation
“…A test on XLPE material showed that although differences are limited, PDIV seems to be lower when testing with a lower frequency rather than a higher one [88]. Field experiences (paper, EPR, and XLPE cable) [99] showed that neither 0. Energies 2021, 14, x FOR PEER REVIEW 8 of 21 circumstances.…”
Section: Off-line Testmentioning
confidence: 96%
“…A test on XLPE material showed that although differences are limited, PDIV seems to be lower when testing with a lower frequency rather than a higher one [88]. Field experiences (paper, EPR, and XLPE cable) [99] showed that neither 0.1 Hz nor DAC can always give close inception PD voltage compared with 50 Hz and the maximum difference is about 200%. The PD tests mentioned above are summarized in Table 3.…”
Section: Off-line Testmentioning
confidence: 97%
“…Величина випробувальної напруги перевищує величину робочої напруги кабелю в 2-6 разів, що може призвести до пробою ізоляції кабелю, який не мав небезпечних дефектів і в нормальних умовах міг би ще працювати певний час. В літературі [4][5][6][7][8][9] розглядаються сучасні способи та засоби періодичного та безперервного неруйнівного контролю технічного стану силових КЛ, однак можливість їх застосування для моніторингу високовольтних та низьковольтних кабелів систем електропостачання військових аеродромів до кінця не досліджена.…”
Section: вступunclassified
“…The physics and causes for PD defects in XLPE and PILC cable systems is mainly well known and described in detail in several publications [1][2][3][4][5].…”
Section: Important Parameter For Pd Diagnosismentioning
confidence: 99%