2021
DOI: 10.11607/ijp.6502
|View full text |Cite
|
Sign up to set email alerts
|

Comparison Between Accuracy of Posts Fabricated Using a Digital CAD/CAM Technique and a Conventional Direct Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 0 publications
0
17
0
Order By: Relevance
“…This finding agrees with another study, where conventionally cast post and cores had better apical adaptation than 3D-printed Co-Cr post and cores. 51 …”
Section: Cad/cam Vs Conventionally Fabricated Post and Coresmentioning
confidence: 99%
See 1 more Smart Citation
“…This finding agrees with another study, where conventionally cast post and cores had better apical adaptation than 3D-printed Co-Cr post and cores. 51 …”
Section: Cad/cam Vs Conventionally Fabricated Post and Coresmentioning
confidence: 99%
“…More recently, the use of milled, 50 and 3D-printed 51 Co-Cr alloy has been reported in in vitro studies, which were compared to cast post and cores. Although many of the other materials used were described in case reports, there is no report on clinical use of CAD/CAM fabricated Co-Cr alloy, possibly due to the inherent aesthetic disadvantage of metal alloys, especially given the numerous alternatives that offer superior aesthetic properties.…”
Section: Materials Used To Fabricate Cad/cam Post and Corementioning
confidence: 99%
“…In an in vitro study, Kanduti et al [46] investigated the influence of the manufacturing method of P+C made of a cobalt-chromium alloy on the accuracy of fit. They fabricated P+C conventionally molded and cast, as well as digitally by an IOS using scanpost and laser sintering of the CAD/CAM-P+C, and found a better fit for the conventionally fabricated P+C [46]. They determined the accuracy of the fit on four horizontal sections reconstructed by superimposing µ-CT data [46].…”
Section: Accuracy Cad/cam-p+c (Part B)mentioning
confidence: 99%
“…They fabricated P+C conventionally molded and cast, as well as digitally by an IOS using scanpost and laser sintering of the CAD/CAM-P+C, and found a better fit for the conventionally fabricated P+C [46]. They determined the accuracy of the fit on four horizontal sections reconstructed by superimposing µ-CT data [46]. In comparison, the mean deviations of the accuracy of fit of the CAD/CAM-P+C in the measurement areas of the first and second root canal third were in a similar range.…”
Section: Accuracy Cad/cam-p+c (Part B)mentioning
confidence: 99%
See 1 more Smart Citation