Comparison Between Digital and Synthetic 2D Mammograms in Breast Density Interpretation

Abstract: Overall, synthetic 2D mammography is comparable with digital 2D mammography in assessment of breast density, though there is some variability by reader. Practices can readily adopt synthetic 2D mammography without concern that it will affect density assessment and subsequent recommendations for supplemental screening.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 25 publications
(6 citation statements)
references
References 19 publications
0
5
0
1
Order By: Relevance
“…A trend toward downgrading BI-RADS density at screening with synthetic mammography versus digital mammography was reported in two recent retrospective studies of outcomes of synthetic mammography and DBT screening (15,22). Also, two retrospective studies (23,24) with 200 and 309 women reported comparable breast density assignments by using digital mammography and synthetic mammography images. To our knowledge, ours is the first large-scale study to evaluate the effect of mammographic screening modality on breast density readings in actual clinical practice where digital mammography and synthetic mammography images are read together with the quasithree-dimensional DBT volume since DBT is acquired.…”
Section: Discussionmentioning
confidence: 85%
“…A trend toward downgrading BI-RADS density at screening with synthetic mammography versus digital mammography was reported in two recent retrospective studies of outcomes of synthetic mammography and DBT screening (15,22). Also, two retrospective studies (23,24) with 200 and 309 women reported comparable breast density assignments by using digital mammography and synthetic mammography images. To our knowledge, ours is the first large-scale study to evaluate the effect of mammographic screening modality on breast density readings in actual clinical practice where digital mammography and synthetic mammography images are read together with the quasithree-dimensional DBT volume since DBT is acquired.…”
Section: Discussionmentioning
confidence: 85%
“…BI-RADS density classification of synthetic 2D mammograms derived from DBT has been compared with with standard DM, with good agreement for individual readers (80%; Cohens kappa 0.73) and excellent agreement when images were dichotomised into dense and non-dense (92%) (138). Good agreement has also been demonstrated for Hologic Selenia Dimensions 'C-View' synthetic mammograms and standard Selenia DM using LIBRA (139).…”
Section: Dbt and Synthetic 2d Dmmentioning
confidence: 96%
“…Two laboratory studies have shown comparable breast density assessment in synthetic 2D images and conventional DM images (212,213…”
Section: Subjective Breast Density Assessment In Digital Breast Tomosmentioning
confidence: 99%